Summary of Contents for Invacare Dolomite Step Up

  • Page 1 Dolomite Step Up® 1521677, 1521678, 1521679, 1536121, 1536122, 1579540, 1585401, 1587608, 1587609 en Walking table User Manual 1521677 1585401 1536121 1521678 1587608 1521679 1536122 1579540 1587606 This manual MUST be given to the user of the product. BEFORE using this product, this manual MUST be read and saved...
  • Page 2 All rights reserved. Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted.
  • Page 3: Table Of Contents

    Contents 1 General ......... 1.1 Introduction .
  • Page 4: General

    Before reading this document, make sure you have the For further information about local standards and regulations, latest version. You find the latest version as a PDF on the contact your local Invacare distributor. See addresses at the Invacare website. end of this document.
  • Page 5: Safety

    Safety 2.2 Safety Information about Step Up 2 Safety Electric WARNING! 2.1 General Warnings Risk of injury (due to unintentional movements in product) WARNING! Electronic equipment can be influenced by Radio Risk of Serious Injury or Damage Frequence Interference (RFI) Improper use of this product may cause injury –...
  • Page 6: Product Overview

    Dolomite Step Up® • User manual 3 Product Overview 3.4 Labels and Symbols on Product 3.1 Intended Use Identification Label The walking aid is intended to support a person’s ability to stand and walk through gait training. The walking aid is for indoor use only. It may be used in Invaca re REA AB Växjövägen 303...
  • Page 7: Usage

    Usage 4 Usage 4.1 Before Use We do not recommend that the product is issued to anyone without first carrying out a full assessment of their specific needs. To ensure user safety and contribute to the 1. Press down brake pedal A one step in order to activate best rehabilitation, it is important that the user is given directional lock.
  • Page 8: Emergency Stop / Lowering - Step Up Electric

    Dolomite Step Up® Emergency button (see separate section; 4.5 Emergency stop / lowering - Step Up Electric, page 8 Emergency lowering (see separate section; 4.5 Emergency stop / lowering - Step Up Electric, page 8 External battery charger Integrated battery charger Warn- Beeps —...
  • Page 9: Width Adjustment - Frame

    Usage Loosen the knob A which is located under the armrests. 1. Lay the walking table down. 2. Remove screws A. 3. Adjust the frame B to the required width on one side. 4. Reinsert the screws and tighten with a minimum of 10 5.
  • Page 10: Height Adjustment - Step Up Hydraulic

    Dolomite Step Up® 4.9 Rising to a standing position 4.8.2 Height adjustment - Step Up Hydraulic WARNING! Risk of falling – Unevenly distributed weight affects the product's stability. Lift the lever and adjust the support platform to the required height by pulling upwards or pushing gently on the armrests.
  • Page 11: Accessories

    2. To release parking brake, press brake handle/handles A towards handle/handles. For spare parts lists, accessories lists and extra user manuals, contact your Invacare distributor. A distinct click indicates that the brake is in the correct position, so that the wheels are locked.
  • Page 12: Hand Brakes For Models With Directional Lock

    Dolomite Step Up® Engaging Running Brake Press brake handle/handles A slowly towards handles. Adjust the brakes with the adjustment nut on the brake The more you press, the higher the braking force handles A. Engaging Parking Brake The parking brake sets the brake into a locked...
  • Page 13: Basket

    Accessories 5.4 Basket 5.8 IV pole In the basket A the user can keep belongings. The basket is simply attached at the top of the platform support B. 5.5 Tray The IV pole can be mounted on the pillar A and makes it possible to attach a drip bag on the product.
  • Page 14: Wheel 100 Mm

    Dolomite Step Up® 5.11 Wheel 100 mm • The Stand Assist accessory is available for users who need support while standing and consists of a standing Models 1521677, 1521678, 1521679, 1536121, 1536122, plate A, knee support B and a harness.
  • Page 15: Maintenance

    If hand grips are loose do not use the walking aid. hand. Instructions on how to change hand grips can be obtained from your provider or Invacare distributor. When using a high-pressure cleaner or an ordinary jet of Verify brake operation.
  • Page 16: After Use

    Dolomite Step Up® 7.2 Disposal 7 After Use WARNING! Environmental Hazard 7.1 Reconditioning Device contains batteries. This product may contain substances that could This product is suitable for reuse. To recondition the product be harmful to the environment if disposed of...
  • Page 17: Technical Data

    Technical Data 8 Technical Data 8.1 Dimensions and Weights Step Up Manual Step Up Hydraulic Step Up Electric 1521677, 1585401 1521678, 1536121, 1587608 1521679, 1536122, 1579540, 1587609 580 - 670 - 760 mm A Inner width, frame (adjustable) 700 - 790 - 880 mm B Outer width, frame (adjustable) C Outer length 825 mm / 890 mm*...
  • Page 18: Material

    Dolomite Step Up® Sound level 48 dB(A) Type B Applied part Applied Part complying with the specified requirements for protection against electrical shock according to IEC 60601-1. (An applied parts is a part of the medical equipment which is designed to come into physical contact with the patient or parts that are likely to be brought into contact with the patient.)
  • Page 19: Electromagnetic Compliance (Emc) - Guidance And Manufacturer´s Declaration

    Technical Data 8.6 Electromagnetic compliance (EMC) - Guidance and manufacturer´s declaration Guidance and manufacturer´s declaration – electromagnetic emission This product is intended for use in the electromagnetic environment as specified below. The user of the product should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance...
  • Page 20 Dolomite Step Up® Portable and mobile RF communications equipment should be used no closer to any part of the product including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance:...
  • Page 21 Technical Data • At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. • These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 1532567-G...
  • Page 22 Notes...
  • Page 23 Notes...
  • Page 24 Invacare Sales Companies Ireland: United Kingdom: Invacare Ireland Ltd, Invacare Limited Unit 5 Seatown Business Pencoed Technology Park, Campus Pencoed Seatown Road, Swords, County Bridgend CF35 5AQ Dublin Tel: (44) (0) 1656 776 222 Tel : (353) 1 810 7084...