Operation

7
Operation
The device has been designed for use in a system complying with the Profinet standard.
For successful operation, the controller must also support all functions and interfaces
described in this document.
7.1
Device Classification
The Profinet Card is a Profinet IO-Device and must be managed by an IO-Controller over
Ethernet.
7.2
Ensuring Safe and Successful Control
Data written to the device will remain in its registers until the data is overwritten or the
device is reinitialised.
If the soft starter may be controlled via Command Override (parameter 7A) or may be
disabled via the reset input (terminals 10, 11) fieldbus commands should be cleared from
the registers. If a command is not cleared, it will be re-sent to the starter once fieldbus
control resumes.
7.3
Feedback LEDs
Port 1
LED name LED Status
Error
Off
Flashing
On
Status
Off
Flashing
Link x
Off
On
TX/RX x
Flashing
4
TX/RX2
TX/RX1
Port 2
LINK 2
Description
No error.
Connection not established.
No physical link or slow physical link.
No configuration.
No error.
DCP signal service initiated via the bus.
No network connection.
Connected to a network.
Transmitting or receiving data.
STATUS
LINK
1
ERROR
Profinet Card