Installation; Manual Control - King gates Dynamos 24/400 Installation And Use Instructions And Warnings

Electromechanical gearmotor for the automation of sliding gates
Hide thumbs Also See for Dynamos 24/400:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11

5 - Installation

Read the instructions with care before installing the product.
The producer disclains all responsibility for any damage or bad
functioning caused by non-osservance of the instructions or bad
connection that may result in poor safety and functioning of the
gear-motor.
5.1 Plate fixing
Tighten the two foundation tie-beans on the plate with the two
M10 nuts (pic.2).
In accordance with the size, fix the plate on a concrete base of
adeguate dimension, complying with fixing distances which have
to be vertical and parallel to the gate.
Arrange one or more sheaths for electric cables (pic.3).
Once the base has hardened, loose the nuts, place the gear-
motor on the foundation plate ascertaining it is parallel to the
gate, and gently tighten the two nuts provided (pic.4).
5.2 Rack fixing
Set the gear-motor on manual functioning (pic.10).
Wide open the gate's door. Place the rack, place the first element
on the pinion and fix it with M6 screws to the gate (pic.5).
Move the door manually and repeat the procedure with the other
elements using a distance spacer to ensure the correct position
from the rack (pic.6).
It is advisable to leave 2mm between the rack the gear to avoid
the gate resting on the gear-motor (pic.7).
5.3 Final adjustment
For the final height adjustment between the motor and the rack,
use the 4 screws located on the external sides for a height up
to 15mm (pic.8). The final fixing of the gear-motor is done by
tightening the 2 nuts placed on the foundation tie/beans.
5.4 Stopping stirrups installing
Move the door to open/close position. Fix the left and right stop-
stirrups on the rack with the screws provided, considering that
when stopping, the gate slides for 2/3 cm more after the limit
switch intervenes (pic.9).Set the motor authomatic functioning
(pic.11).
14

6 - Manual control

m
ATTENTION: before operating the manual release
disconnect the power. The motor is anyway disconnected
during the release, thanks to the presence of a safety
micro-switch.
Manual control has been thought for manual opening of the gate
in case of power-cut or motor breakdown (pic.10).
• Operate the manual release moving back the key hole cover.
• Insert the key in the cylinder lock and turn it of 90° clockwise
direction.
• Pull the lever till it is perpendicular to the gear-motor.
Automation restore (pic.11):
• Bring back the lever in the original position.
• Insert the key in the cylinder lock and turn it of 90°
anticlockwise direction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dynamos 24/600fDynamos 24/1000Dynamos 500Dynamos 1000

Table of Contents