Terminal Box; Equipotential - Gastro-M DS181 Instruction Manual

Table of Contents

Advertisement

Available languages

Available languages

ONCE THE ELECTRIC CONNECTION HAS BEEN PERFORMED, THE AUTHORIZED
TECHNICIAN (ELECTRICIAN) MUST ISSUE A DECLARATION CERTIFYING THE
MEASUREMENT OF THE CONTINUITY OF THE EQUIPOTENTIAL PROTECTION
CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30 MA

TERMINAL BOX

The terminal box is placed externally on the back of the oven.
1/40; 2/40
1/50; 2/50; 3/50

EQUIPOTENTIAL

The equipment must be connected with an equi-potential system . the connection terminal is located near
the terminal box. The bonding wire must have a minimal section of 10 mm ².
17
L1
L2
L3
N
Oven type
Clamp N. 1
Clamp N. 2
Clamp N. 3
Clamp N. 5
Clamp N. 6
N. of cables
Section (mm²)
3
5
2,5
4