Page 1
USER GUIDE FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS User Guide Rev. 1.99 Doc. ID: 1061-6259 www.kontron.com // 1...
Page 2
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 This page has been intentionally left blank www.kontron.com // 2...
Page 3
Kontron with respect to technical processes described in the user guide or any product characteristics set out in the user guide. Kontron assumes no responsibility or liability for the use of the described product(s), conveys no license or title under any patent, copyright or mask work rights to these products and makes no representations or warranties that these products are free from patent, copyright or mask work right infringement unless otherwise specified.
Page 4
ENVIRONMENTAL DAMAGE (COLLECTIVELY, “HIGH RISK APPLICATIONS”). You understand and agree that your use of Kontron devices as a component in High Risk Applications is entirely at your risk. To minimize the risks associated with your products and applications, you should provide adequate design and operating safeguards.
Page 5
Kontron sells products worldwide and declares regional General Terms & Conditions of Sale, and Purchase Order Terms & Conditions. Visit http://www.kontron.com/terms-and-conditions. For contact information, refer to the corporate offices contact information on the last page of this user guide or visit our website CONTACT US.
Page 6
If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the revised user guide on our website.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Symbols The following symbols may be used in this user guide DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are requested to conform with the following guidelines.
General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the product, that are not explicitly approved by Kontron and described in this user guide or received from Kontron Support as a special handling instruction, will void your warranty.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Table of Contents Symbols............................................7 For Your Safety ......................................... 8 High Voltage Safety Instructions ..................................8 Special Handling and Unpacking Instruction ..............................8 Lithium Battery Precautions ....................................9 General Instructions on Usage ....................................
Table 10: Technical Data FlatClient ECO Line with Intel® Pentium® CPU N4200/Intel® Celeron® J3455 ......30 Table 11: Current Rating at 12 V for FlatClient ECO Line with Intel® Pentium® CPU N4200/Intel® Celeron® J3455 ..30 Table 12: Technical Data FlatClient PRO Line with Haswell and Broadwell processors ............31 Table 13: Current Rating at 12 V for FlatClient PRO Line with Intel®...
1/ Introduction With its FlatClient Monitor series, Kontron offers high mechanical flexibility with respect to the design. It can be used both as a full-metal solution with VESA 75/75 respectively 100/100 as well as a built-in solution. The front comes with standard IP65 protection, with the full-metal variant offering a standard IP54.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 2/ General Safety Instructions for Electronic Devices Please read this passage carefully and take careful note of the instructions, which have been compiled for your safety and to ensure to apply in accordance with intended regulations.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 a reliable protective earthing connection is provided a suitable, easily accessible disconnecting device is used in the application (e.g. overcurrent protective device), if the device itself is not disconnect able ...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 La manipulation et le fonctionnement du produit ne sont autorisés que pour le personnel formé dans un lieu de travail dont l'accès est contrôlé.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 2.5. Electrostatic Discharge (ESD) A sudden discharge of electrostatic electricity can destroy static-sensitive devices or micro-circuitry. Therefore, proper packaging and grounding techniques are necessary precautions to prevent damage.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 3/ Scope of Delivery This chapter describes the components that are delivered and can be optionally ordered. Please check that your delivery is complete and contains the items below (according to the ordered unit configuration).
Page 20
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Part Number Part Description PR22-100007-01 Adapter VGA - DisplayPort 1.1, Delock: 65567 PR22-100008-01 Adapter DVI-I – HDMI, Delock: 65467 840-0758 DisplayPort cable 1,8m 840-0759 DisplayPort cable 3m...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 3.1.1. Type Label and Product Identification Product and Package Label, size 85 x 35mm, polyester matt silver. Certification print Figure 2: Type Label Short Description...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 4/ Order Information E N 0 0 - y y y y y y - x x EN00- 4GB RAM/32GB M.2 4GB RAM/64GB M.2 4GB RAM/128GB M.2 4GB RAM/256GB M.2...
Page 23
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 EN00- with Touch resistiv and stainless steel front (STS) with Touch PCAP and stainless steel front (STS) with Touch PCAP V2 with Protection glass V2...
Page 24
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 EN00- Projects 7.0" SLU2 Skylake i5-6300U only Projects 65.0" APL4 Apollolake N4200 only Projects 65.0" SLU2 Skylake i5-6300U only 10.1" APL4 Apollolake N4200 10.1" SLU2 Skylake i5-6300U 12.1"WXGA...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Figure 4: Bottom View Description – FlatClient ECO (BayTrail) Full-metal variant VGA connector USB 2.0 2x HDMI port VESA Mounting holes LAN interface 2x Power connector USB 3.0...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 6/ Technical Data and Environmental Specification Table 4: Technical Data FlatClient ECO and FlatClient PRO Line Display Size 7.0" 10.1“ 10.4“ 12.1“ SVGA 12.1“ XGA...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Table 6: Technical Data FlatClient ECO and FlatClient PRO Line Display Size 15.6“ Full HD 17.0“ 18.5“ HD 18.5“ Full HD Slim Resolution 1920x1080, Full...
Card Memory on demand, mSATA SSD 32 GB, 64 GB, 128 GB, 2x COM (RS232, RS422, RS485), Audio with amplifier (2x 3 W), RFID, WiFi (on demand) Table 9: Current Rating at 12 V for FlatClient ECO Line with Intel® Celeron Quad Core J1900 Display Size Current [A] 7.0"...
Memory on demand, m.2 SSD 32 GB, 64 GB, 128 GB, 256 GB, 512 GB, 2x COM (RS232, RS422, RS485), Audio with amplifier (2x 3W), RFID, WiFi (on demand) Table 11: Current Rating at 12 V for FlatClient ECO Line with Intel® Pentium® CPU N4200/Intel® Celeron® J3455 Display Size Current [A] 10.1"...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Table 14: Technical Data FlatClient PRO Line with Skylake, Whiskey Lake and Kaby Lake CPU Intel® Skylake ULT Intel® Kaby Lake ULT Intel® Whiskey Lake Core™...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Table 16: Environmental Specification FlatClient ECO and FlatClient PRO Line Operating Altitude Up to 3000 m (9900 ft) Storage Altitude Up to 5000 m (16500 ft) Humidity 10%-90% @ 39°C, non condensing...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.2.2. Power-Switch and LEDs Figure 10: Power-Switch and LEDs Power on LED Power LED Drive Activity Table 18: Button Functions (1) Button Functions Activity Pressed during active system...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Table 28: Button Functions (2) Button Functions Activity Pressed during active system OS is put into sleep state Pressed when power LED is OS is started from sleep state...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.3.8. DB15 VGA Connector Table 35: Pinout VGA Connector Signal Name Signal Name Green Blue n.c. n.c. DDC Data Hsync Vsync DDC Clock 8.3.9. COM2 RS-232/422/485 (via internal cable connection to CN16, Option)
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.4. FlatClient PRO Haswell Figure 15: Interfaces for Panel PC PRO variant LAN interface 3x Earth stud DisplayPort 2x Power connector USB 3.0 4x Power/LEDs 8.4.1.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.4.2. Power-Switch and LEDs Figure 18: Power-Switch and LEDs Power on LED Power LED Drive Activity Table 37: Power On Button Functions (1) Button Functions...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.4.4. GbE RJ-45 Connector Table 41: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+ TX4+ TX3+ TX4- 8.4.5. LED Diagram of LAN Connectors...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.5. Flatclient PRO Skylake/Kaby Lake/Whiskey Lake Figure 19: Interfaces for Panel PC FlatClient PRO Skylake/Kaby Lake variant HDMI Earth stud DP connector Power connector 2x GbE 4x USB 3.0...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.5.2. Power-Switch and LEDs Figure 22: Power-Switch and LEDs Power LED Power On LED Drive Activity Table 44: Power LED (1) Signal No Power Green...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 8.5.4. GbE RJ-45 Connector Table 48: Pinout GbE RJ-45 Connector Signal Name Signal Name TX1+ TX3- TX1- TX2- TX2+ TX4+ TX3+ TX4- 8.5.5. LED Diagram of LAN Connectors...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 9/ Installation and Start 9.1. Mounting Instructions (built-in-variant only) Fixation screw torque is 0,8 Nm +/- 0,2 Nm. Step Installation Description Use mounting set with screws and clamping brackets ...
Page 84
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Step Installation Description Fix the bracket with the screw to the housing Repeat step 4 for all positions of clamping bracket Wall-/Switch cabinet doors thickness has to be at least 3 mm. Otherwise use an adapter frame or adapter brackets.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 9.2. Startup Procedure To activate your FlatClient Panel PC connect the power supply to power connector on the FlatClient back side. Alternative use the mating power connector for connecting your power cable. The LED “PWR” gives a green or blue light now.
RMA number. The buyer accepts responsibility for all freight charges for the return of goods to Kontron's designated facility. Kontron will pay the return freight charges back to the buyer's location in the event that the equipment is repaired or replaced within the stipulated warranty period. Follow these steps before returning any product to Kontron.
Page 87
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Fax: +49 (0) 821 4086 111 Email: service@kontron.com The goods for repair must be packed properly for shipping, considering shock and ESD protection. Goods returned to Kontron Europe GmbH in non-proper packaging will be considered as customer caused faults and cannot be accepted as warranty repairs.
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 Appendix A: List of Acronyms Application Programming Interface Base Management Controller Command-Line Interface Computer-on-Module Error Checking and Correction Field Replaceable Unit Graphics Processing Unit HD/HDD...
FlatClient ECO and FlatClient PRO, FlatClient RCK and FlatClient STS – User Guide Rev. 1.99 About Kontron – Member of the S&T Group Kontron is a global leader in Embedded Computing Technology (ECT). As a part of technology group S&T, Kontron offers a combined portfolio of secure hardware, middleware and services for Internet of Things (IoT) and Industry 4.0 applications.
Need help?
Do you have a question about the FlatClient ECO and is the answer not in the manual?
Questions and answers