OSF poolcontrol-30 Installation And Operating Manual

230v filter control unit with solar control

Advertisement

Quick Links

Installation and operating manual
-30
230V filter control unit with solar control
Item No.: 310.000.0530

Function

The
PC-30 filter control unit allows time-dependent switching on and off of a 230 V
alternating current filter pump in accordance with a freely-programmable switching
program.
heater of the swimming pool is controlled by the electronic temperature regulation system
while the filter pump is running. The heater is automatically switched off by the internal
interlock during filter pauses. The required swimming pool water temperature can be
selected on the front panel, or the heater can be switched off. A floating contact (terminals
22 + 23) and a 230 V output (terminals U2 and N) are available for connecting the
heating. Terminals for a
solar actuating drive are available for operation with solar
absorbers through which the swimming pool water flows directly.
The integrated frost protection function makes the swimming pool winter break easier to
deal with.
Terminals for electronic level regulation NR-12-TRS-2 (Art. No. 3030075020) enable
convenient automatic regulation of the swimming pool water level. The filter pump is also
additionally protected against damage which could be caused by filter unit operation
without water.
Bar valves for backflushing and rinsing can be connected directly to the PC-30 so that
separate backflushing control units are not necessary. If a 6-way valve is to be used for
backflushing, additional terminals for an
EUROTRONIK-10 enable extension of the
filter control unit to an automatic filter and backflushing control unit for 6-way valves.
Extra terminals enable the connection of additional devices such as a dosing system.
Terminals 20 + 21 are floating, and can therefore be used individually. The relay contact
between terminals 20 and 21 remains closed during the filter periods, the relay contact is
opened outside these periods. This contact can be loaded with a voltage of maximum 230
V and a current of maximum 4 A.
Operation of filter pump and heater is displayed by indicator lamps in the front panel,
which means that checks can be made at any time.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the poolcontrol-30 and is the answer not in the manual?

Questions and answers

Summary of Contents for OSF poolcontrol-30

  • Page 1: Function

    Installation and operating manual 230V filter control unit with solar control Item No.: 310.000.0530 Function PC-30 filter control unit allows time-dependent switching on and off of a 230 V alternating current filter pump in accordance with a freely-programmable switching program. heater of the swimming pool is controlled by the electronic temperature regulation system while the filter pump is running.
  • Page 2: Table Of Contents

    PC-30 Filter control unit operating manual Page: 2 Contents Function................................ 1 Contents................................ 2 Specifications............................... 3 Installation..............................3 Electrical power supply..........................3 Mains connection and filter pump connection................... 3 Heater connection............................ 4 Level regulation and backflushing control....................4 Further connection facilities........................5 Temperature sensor..........................
  • Page 3: Specifications

    PC-30 Filter control unit operating manual Page: 3 Specifications Dimensions: 220mm x 219mm x 100mm Operational voltage: 230V/50Hz Control system power consumption: ca. 10VA Switching capacity: Pump: max. 1.1 kW (AC3) Heater: max. 230V/4A Dosing system: max. 230V/4A Protection class: IP 40 Installation The controller must be mounted protected against moisture in accordance with its...
  • Page 4: Heater Connection

    PC-30 Filter control unit operating manual Page: 4 Heater connection Floating contact (e.g. for 230V heater (e.g. circulation Solar heating boiler control) pump) PC-30 PC-30 PC-30 22 23 Heater floating Heater 230V Solar- max. 4A max. 4A actuator 230V The floating relay contact between terminals 22 and 23 can be loaded with a voltage of maximum 230 V and a current of maximum 4 A.
  • Page 5: Further Connection Facilities

    PC-30 Filter control unit operating manual Page: 5 Further connection facilities Filter control PC-30 20 21 Dosing system (floating) max. 230V / 4A There is a floating relay contact between terminals 20 and 21. This can, for example, be used for activation of the dosing system (the contact remains closed during filter operation).
  • Page 6: Front Panel Displays And Controls

    PC-30 Filter control unit operating manual Page: 6 Front panel displays and controls: Solar operation indicator lamp Solar heater ON/OFF Heater indicator lamp Heater ON/OFF Set temperature INFO-key Set switching times Backflushing indicator lamp Filterpump indicator lamp Set backflushing Select operating mode LCD-display Operating mode indicator lamp Setting keys...
  • Page 7: Heater Indicator Lamps

    PC-30 Filter control unit operating manual Page: 7 Heater indicator lamps This indicator lamp displays heater operation. You can see the heater operating mode from the lamp colour: Off: the heater is off Green: the heater is in operation Red: the additional heater is blocked. Use the key to block or release the heater.
  • Page 8: Programming The Timer

    PC-30 Filter control unit operating manual Page: 8 You can now use the keys to set the hours. key ⇒ the weekday display blinks. Press the You can now use the keys to set the weekday. Press the key again to save the time. If no key is pressed for more than 10 seconds during setting, the last time displayed is saved automatically and the normal operating display will be shown again.
  • Page 9: Programming Backflushing

    5 seconds, backflushing will be triggered. Info key When you press the INFO key, the program version number will be osf PC30 displayed first. ver.1.00 . After this you can press the key again to...
  • Page 10: Fuses

    16A on site. Service terminal An osf service terminal (Art. No. 3010000900) can be connected to this control system for optimum control system settings for a wide range of swimming pool equipment and for assisting in initial startup and fault diagnosis.
  • Page 11: Heater Operating Mode

    PC-30 Filter control unit operating manual Page: 11 by the temperature regulation system because this works in the priority circuit. Pump blocked The filter pump is switched off temporarily by the EUROTRONIK-10 or the NR-12-TRS-2 level regulation system. Backflushing The filter pump is switched on because backflushing is taking place using the bar valve.
  • Page 12: Set Temperature

    PC-30 Filter control unit operating manual Page: 12 Set temperature The set temperature is displayed in this line, and this is set using the key in the front cover. Solar difference This line displays how much warmer the solar collector needs to be than the swimming pool water before the solar heater is switched on.
  • Page 13: Additional Heater Minimum Time

    PC-30 Filter control unit operating manual Page: 13 Once the key has been pressed, the filter unit is switched off and the display shows the following: Limit temp.: 40,0 ° Maximum possible water temperature at solar operation Now use the keys to change the limit temperature.
  • Page 14: Filter Pump Run-On Time

    PC-30 Filter control unit operating manual Page: 14 Filter pump run-on time This line displays for how long the filter pump runs on after the additional heater has been switched off. This value can be adjusted to meet the requirements of the relevant filter unit if it is displayed in the top line: Once the key has been pressed, the filter unit is switched off and the display...
  • Page 15: Interlocking

    PC-30 Filter control unit operating manual Page: 15 EUROTRONIK ON The EUROTRONIK-10 has switched the filter pump on Interlocking This line displays whether the filter unit has been switched off either by the EUROTRONIK-10, -12-TRS-2 or the coil earthing contact. The following displays are possible: Interlock OFF The pump is switched off (one of the contacts is open).
  • Page 16: Filter Pump

    PC-30 Filter control unit operating manual Page: 16 Once the key has been pressed, the filter unit is switched off and the display shows the following: Prior.solar Priority switch for solar heater Use the key to switch the priority circuit on, and the key to switch it off.
  • Page 17: Dosing Unit

    PC-30 Filter control unit operating manual Page: 17 Once the key has been pressed, the filter unit is switched off and the the following is displayed: Heater MANUAL OPERATION Heater: Filter pump: Use the key to switch the additional heater on, and the key to switch it off.
  • Page 18: Language

    PC-30 Filter control unit operating manual Page: 18 Language If the language is displayed in the top line of the service terminal it can be switched over. If you press the key, the following is displayed: Language selection German English Now use the keys to change the selected language.