Electrical Controls Sequence Of Operation; Electrical System Specifications - Vestil HDC-905 Series Instruction Manual

Hydraulic drum crushers
Hide thumbs Also See for HDC-905 Series:
Table of Contents

Advertisement

Rev. 2/21/2017

Electrical controls sequence of operation:

NOTE: These instructions apply to all HDC-905-IDC units manufactured after June 2011, i.e. units equipped with manifold
22-127-008 rev C and wired according to electrical circuit diagram 22-124-024 rev D.
1) Press "Cycle start" button
-
1M energizes;
-
Aux. contacts 13 and 14 close;
-
Terminal 8 energizes;
-
Power at CR2 9&1;
-
Power reaches 2LS normally open, held closed switch (NO, HC);
-
Power on 11 to CR1, 13 and 14;
-
CR1, 5 and 9 close (latch);
-
CR1, 2 and 10 open (timer);
-
Energize 2 SOL H (4-way, 3-position);
-
Ram and platen descend.
2) As the ram and platen descend:
-
2 LS normally closed, held open switch (NC, HO) closes;
-
2 LS NO, HC opens;
-
Motor runs without button contact.
3) At full extension of piston rod and platen:
-
PS1 (if in "CRUSH" mode) or PS2 (if in "COMPACT" mode) make;
-
Energizes CR2, 13 and 14;
-
CR2, 9 and 1 open;
-
2 SOL H de-energizes;
-
CR1, 13 and 14 de-energize;
-
CR1, 2 and 10 close and the timer starts.
4) Timer cycle:
-
CR1, 3 and 11 close;
-
Power reaches decompression valve 3 SOL H;
-
1-2 second delay after which power reaches CR3, 13 & 14;
-
CR3, 2 and 10 open;
-
3 SOL H de-energizes and closes;
-
CR3, 5 and 9 close;
-
Power to 1 SOL H causing the ram and platen to ascend.
5) As the piston rod retracts and returns the platen to the ready position:
-
2 LS normally closed switch opens; and
-
1M de-energizes.

Electrical system specifications:

This drum crusher was tested at the voltage specified at the time of order. To adapt to applications requiring voltages
that differ from your original specifications requires rewiring the motor and control transformer. Refer to the appropriate
electrical circuit diagram on pp. 11-14. Failure to rewire the motor and/or transformer automatically voids the "Limited
Warranty" (see p. 18 or 19) and might significantly damage the electrical system.
This table indicates how to wire 3-phase motors for 208-230VAC and 460VAC:
208-230VAC, 3-phase
Motor wire
1 & 7
2 & 8
3 & 9
4,5, & 6
Copyright 2017 Vestil Manufacturing Corp.
Connect to contactor lead
T1
T2
T3
Tie together with wire nut
460VAC, 3-phase
Motor wire
Connect to contactor lead
1
T1
2
T2
3
T3
4 & 7
Tie together
5 & 8
Tie together
6 & 9
Tie together
HDC-905, MANUAL
Page 10 of 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdc-905-idcHdc-905-hc

Table of Contents