correct value.
Once correct parameter is set, program will automatically return to default function after short period of time.
After finish welding (longer than 5s), average values are prepared and shown on display by short period
of time. That values are accessible after as the last functions and reachable by pressing encoder button
3.1 Start up Display
4.2.4 Start-up Display
P.5.9.8.
1
8.1.0.0.
L.S.-. 1.
2
8.5.0.0.
L.S.-.2.
3
8.3.0.0.
L.S.-.3.
4
8.4.0.0.
SECTION 4 — OPERATION

3.2 Standard Display Functions

4.2.5 Standard display functions
8.8.8.8
5
8.8.8.8.
8.8.8.8
6
*
8.8.8.8.
8.8.8.8.
7
8.8.8.8
*
_._._.U.
8
8.3.3.A
*
~.~.~.U.
9
8.3.3.A
*
1.0.0.U
10
*
8.3.3.A
*
1.0.0.U.
11
8.3.3.A.
-.-.-.-.
12
-.-.-.-.
d.u.r.8.
13
8. 1. 1.3.
d.u.r.8.
14
C.L.r.8.
14
R4000/5000CC/CV
Program no. and version display
Settings Check
Maximum current set for MMA mode
Settings Check
Maximum current set for MIG mode
Settings Check
Maximum current set for TIG mode
R5/4000 CCCV
Top, right decimal point constantly ON
Top, right decimal point flashing
Bottom, right decimal point flashing
Dashes on the bottom of the voltage display and
current flow diode flashing
Dashes on the top of the voltage display and cur-
rent flow diode flashing
Voltage and current display with
U and A characters
Voltage and current display with flashing U and A
characters
Change mode
Welding time duration
Only during display start
Function accessible when encoder button
press long during start-up.
This is info only, no changes are possible.
LED4 (bottom) is flashing when mode is
available (mode availability is specified by
software version)
Restart is necessary to stop display
Remote control detected
Output voltage detected (when output volt-
age >5V and no remote connected)
Current flow detected (when current flow
>5A)
Current flow and output voltage too low
(<5V)
Current flow and output voltage too high
(>50V)
Actual current and voltage readings
Average welding conditions from the last
job. That function is automatically displayed
after stop current flow but is also accessible
as a menu function.
Minimum current flow time to activate func-
tion is 5s
Mode is selected by turning encoder. Cur-
rently selected mode is indicated by one of
the LED diodes
Personal time counter in minutes.
Every decimal point = 6min
Maximum value 999.9min
Long press to reset value
After long press counter is resetting and mes-
sage "dur.clr" displayed for short time
9