Gastype
B (min. -
A1 (min. -
max.)
max.)
Nat. gas
1 - 2,5 m
1,0 - 10,0 m
Propane
(A1 + A2 : B) : 1 Proportion vertical: horizontal (or 45
all dimensions are exclusive the length of the roof outlet

Wall outlet

Always allow one metre vertical before passing through the outer wall.
The maximum length for a horizontal segment is 3 metres.
Determine the location of the appliance and the exterior wall duct.
Make an opening of Ø 160 mm for the wall duct.
Connect the wall duct vertically with a curve to the mouth of the appliance, push them firmly together and place the clip
binding. The blue rubber ring ensures sufficient sealing of the outlet of the flue gas system.
If the appliance is placed more than 1 meter from the outside wall, place the first meter on top the appliance, then the elbow
followed by the wall outlet. Finally make sure the construction is gastight.

Roof outlet

The roof outlet may pass through any point of the roof, with a bend to the ridge, if so desired. The roof outlet is supplied with
a universally adjustable plate for a sloped roof, or with an adhesive plate for a flat roof.
Determine the location of the hearth and the roof outlet.
Make an opening of Ø 160 mm.
Connect the pipes vertically to the outlet of the hearth, press it in place and secure it with the clip.
Determine the length of the pipes you need, and ensure that the adhesive strip or the universal tile is properly linked up with
the roof.
Saw the outer pipe off to measure and link the roof outlet to the concentric pipes.

Placing the pipe system first and then placing the hearth

You can also place the concentric pipe system before placing the appliance. In such case, ensure that you make the connection
with the appliance with an extendable pipe.

Opening the door

The door can be opened by unscrewing the screws as pointed out on the image on the next page. The upper and lower panels
are attached with magnets and can easily be removed.
Watch out for finger marks!
Make sure to leave no finger marks on the cleaned glass pane when you close the hearth door. Finger marks
leave stains which will burn in the glass.