CE Approved GSI/FFI Portable
Dryer Manual
Operation Manual
PNEG-1717
Date: 03-27-14
PNEG-1717

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1100 Series and is the answer not in the manual?

Questions and answers

raymond mccormack
May 18, 2025

how much does the GSICOMPETOR118 SERIES100 wei

Summary of Contents for GSi 1100 Series

  • Page 1 CE Approved GSI/FFI Portable Dryer Manual Operation Manual PNEG-1717 Date: 03-27-14 PNEG-1717...
  • Page 2 Models: 1100 Series (Models 1108, 1112, 1114, 1116, 1118, 1120, 1122, 1126, CFAB190, CFAB270, CFAB320, CFAB370, CFAB400, CFAB460, CFAB510, CFAB511, CFAB601) 1200 Series (Models 1214, 1216, 1218, 1220, 1222, 1226, C2120A, C2122A, C2125A, C2130A, C2132A, C2140A) 1200S Series (Models 1214S, 1218S, 1220S, 1222S, 1226S, CF2141, CF2181, CF500H,...
  • Page 3: Table Of Contents

    Timer and Delay Settings ........................36 Setting the Temperatures ........................36 Start-Up ............................... 36 Continuous Flow Drying Mode Using Regulation of Grain Temperature ..........37 Continuous Flow Drying Mode Using Regulation of Moisture: 5 MR SP ..........41 PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 4 Chapter 11 Vision Schematics and Wiring Diagrams ..................62 Fan/Heater Standard ......................... 62 Front Panel ............................63 Upper Control Box ..........................85 380-400 VAC 3 Phase ........................86 Ladder Diagram ..........................87 Chapter 12 Warranty ............................91 PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 5: Chapter 1 Introduction

    11. DO NOT allow foreign material to be drawn into the fan. 12. When drying products not included in this manual refer to GSI for further precautions and instructions. 13. Check for leaks at least every day. Repair before operation.
  • Page 6: Chapter 2 Safety

    Please observe all safety decals on the equipment. Safety decals on this equipment use the following system: HAZARD Example: Rotating auger PROHIBITION Example: No smoking or naked flames MANDATORY ACTION Example: Wear ear defenders Instructions for your safety PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 7: Emergency Stop Switch

    2. Safety Emergency Stop Switch In event of emergency press the Emergency Stop to stop all dryer equipment (power remains connected). PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 8: Chapter 3 Installation

    7. Maximum towing speed is lowest of 70 km/h or statutory speed limit. 8. After first 80 km and every 300 km check: a. Wheel bearing temperature <= 65°C. b. Wheel nuts torque = 160 Nm. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 9: Location Of The Dryer

    3. After the initial fill the system will run to maintain the dryer level. 4. Dryer fill is monitored by the out of grain timer. (Refer to PNEG-1710 for setting this timer.) 5. Dryer shuts down when out of grain. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 10: Electrical Power Supply

    Load and discharge conveyors connected into the dryer must not exceed electrical load information in Specifications Chapter on Pages 15-25. Motors exceeding these must be powered separate from the dryer with separate contactor and overload device for each motor. Control may still be performed by the dryer. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 11: Fuel

    1389 T 14.2 M 14.2 B (U+L) 11.2 3620/1500H 7915 1174 (T+M+B, U+L) 10.2 3626/2000M 11433 1646 (T+M+B, U+L) 11.2 * Maximum line size for 30m length. ** Maximum burner pressure 450 mBar. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 12 9381 T 16.6 M 16.6 B (U+L) 13.7 3620/1500H 7915 (T+M+B, U+L) 12.9 3626/2000M 11433 1065 (T+<M+B, U+L) 13.7 * Maximum line size for a 100' distance. ** Maximum burner pressure 450 mBar. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 13: Chapter 4 Specifications

    4. Specifications FFI Dimensions Figure 4A Figure 4B PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 14 (31' 2") 4089.4 2438.4 4419.6 3962.4 3581.4 1955.8 2438.4 10109.2 10718.8 2140 (26') (13' 5") (8') (14' 6") (13') (11' 9") (6' 5") (8') (33' 2") (35' 2") NOTE: All dimensions are in mm. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 15: Ffi Specifications

    Electrical Load (Fans, Top and Bottom Augers 380 Volt, 50 Hz, 3 Phase Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate. Excludes auxiliary load and unload conveyor equipment. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 16 Electrical Load (Fans, Top and Bottom Augers 380 Volt, 50 Hz, 3 Phase Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate. Excludes auxiliary load and unload conveyor equipment. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 17: Gsi Dimensions

    4. Specifications GSI Dimensions Figure 4D Figure 4E PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 18 4. Specifications Single Module GSI Transport and Installation Dimensions Values are Valid for Transportation of Stack Modules Dryer Installed Height Transport Installed Height w/o Frame Transport Installed Transport Basket Standard Height Width Wet Bin Width Width Length Length 4089.4 2438.4 4419.6...
  • Page 19: Gsi Specifications

    Electrical Load (Fans, Top and Bottom Augers 3 Phase, 380 Volt Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate. Excludes auxiliary load and unload conveyor equipment. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 20 Electrical Load (Fans, Top and Bottom Augers 3 Phase, 380 Volt Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate. Excludes auxiliary load and unload conveyor equipment. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 21: All Stack Dimensions

    4. Specifications All Stack Dimensions Figure 4G Example of Stack Dryer Footprint PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 22 Figure 4H Side View - 2 Module Stack Dryer “X” - Varies with dryer length (See Chart on Page 23.) Figure 4I Stack Dryer Dimension (Side View - 3 Module Stack Dryer) NOTE: All dimensions are in mm. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 23 8483.6 (27' 10") 9093.2 (29' 10") 9702.8 (31' 10") 10922.0 (35' 10") End View - 2 Module Stack Dryer End View - 3 Module Stack Dryer Figure 4J NOTE: All dimensions are in mm. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 24: All Stack Specifications

    Electrical Load (Fans, Top and Bottom Augers 3 Phase, 380-400 Volt Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate. Excludes auxiliary load and unload conveyor equipment. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 25 Electrical Load (Fans, Top and Bottom Augers 3 Phase, 380-400 Volt Actual discharge rate is controlled by meter roll speed adjustment, at 5% to 100% of maximum rate. Excludes auxiliary load and unload conveyor equipment. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 26 FL-02-2 for details. 32" Thick pedestal required for heat reclaimer option. (See bulletin FL-03-2 for details.) 2. Approximate location of standard service platform shown. See bulletin SP-02-2 for details. For information on optional catwalk, see bulletin CATH-01-5. 3. For safety cage information, refer to bulletin SC-01-2. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 27 FL-02-2 for details. 32" Thick pedestal required for heat reclaimer option. (See bulletin FL-03-2 for details.) 2. Approximate location of standard service platform shown. See bulletin SP-02-2 for details. For information on optional catwalk, see bulletin CATH-01-5. 3. For safety cage information, refer to bulletin SC-01-2. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 28: Stack Dryer Foundation Specifications

    10" (254 mm) Depth with 36" (914.4 mm) wide x 36" (914.4 mm) deep footings along each side. #4 Reinforcing rods on 1' (304.8 mm)-0" centers. Both directions in slab and bottom of footing. Use 3/4" (19.05 mm) x 9-5/8" (244.475 mm) minimum anchors with epoxy. GSI part #: Anchor (GTC-0003) epoxy (GTC-0004).
  • Page 29: Chapter 5 Vision Control Panel

    NOTE: Does not disconnect the power to components in the upper and lower control boxes. Use the main disconnect for this. Fan Switch 1. Selects/deselects each fan. 2. Bottom fan is always # 1. 3. ON (1) = Continuous fan. 4. AUTO (0/1) = Fan operates except during unload. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 30: Heater Switch

    1. AUTO (0/1) = Light OFF when dryer shuts down. Start Switch 1. Starts the dryer subject to other switch settings. Stop Switch 1. Stops all dryer functions. 2. Resets control following fault related shut down. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 31: Chapter 6 Vision Touch Screen Display

    (See Figure 6A.) 3. The Start Dryer button enters the Default Operation screen. Buttons used to update software. (See PNEG-1506 Vision programming manual.) Figure 6A NOTE: See PNEG-1456 for vision touch screen display details. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 32: Chapter 7 Vision Test Firing

    14. Ensure drive chain tension correct and all sections of the meter rolls rotate. 15. Turn the Unload switch OFF. The bottom auger will run for 60 seconds to allow for clean out. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 33: Burner Test Fire

    10. If the flame pops or flutters, the pressure is too low. This can damage the burner. Increase pressure to eliminate. Approximate setting should be: LP Gas Natural Gas High-Fire 450 mBar High-Fire 450 mBar Low-Fire 70-220 mBar Low-Fire 70-220 mBar PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 34 Watch gauge for pressure Throughput adjuster Low-Fire needle valve Pressure regulator (High-Fire) High pressure switch Figure 7A NG Pipe Train Regulator Supply line ball valve Watch gauge for pressure Figure 7B NG Supply Pipe Train PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 35: Dryer Shut Down

    3. Press the Dryer Stop button. 4. Turn OFF the control power. 5. Turn OFF the dryer safety disconnect and turn OFF the main power to the dryer. Emergency In case of emergency, push the Emergency Stop button. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 36: Chapter 8 Vision/Dri-Tek Dryer Operation

    Drying mode options are: 1. Regulation of Grain Temperature on Page 2. Regulation of Moisture: 5 MR SP on Page 3. Regulation of Moisture: Variable MR SP (not recommended for single module dryers). PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 37: Continuous Flow Drying Mode Using Regulation Of Grain Temperature

    Accept/Exit button to set this value into the computer. Grain should begin to run. 13. Run again for 10% longer than the drying time noted from the chart. This will even out, but over dry the grain in the dryer. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 38 20. Set the temperature set point. M/C > Set Temperature Set Point 40°C > ACCEPT. Run on these settings as a starting point before adjusting moisture or meter roll settings. Moisture control will not be precise at this stage. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 39 NOTE: 2 Speed meter roll option works well if the grain entering the dryer has consistent moisture content. For widely varying moisture contents, the 5 Speed option is recommended. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 40 4. Inner and outer limits dictate the points at which the speed increases either side of the set point. These are set as shown in Figure 8G using the INC (increase) and DEC (decrease). PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 41: Continuous Flow Drying Mode Using Regulation Of Moisture: 5 Mr Sp

    8. At this stage, drying must be started manually, following the same procedure given in Step 9 on Page 42 to Step 12 on Page 43 for full heat continuous flow temperature control. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 42 (See Figure 8K on Page 43.) Example: Reading = 18.3%, Sample = 17%, Offset = -1.3%. The moisture tester gives an average moisture of 17%, but the moisture sensor on the dryer reads 18.3%. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 43 Set the manual unloading speed as close as it should be for the grain currently in the dryer before switching to moisture control mode. The manual speed setting does not need to be adjusted after the moisture control is activated. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 44: Chapter 9 Vision Illustrations

    Supply Line (LP Shown) Fan/heater control box Supply line (liquid) solenoid Supply line (liquid) solenoid Plenum air pressure switch Left grain high-limit thermostat Plenum air pressure switch Manual shut off valve Figure 9A PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 45: 28" And 36" Lp 1" Npt Ce Pipe Train Assembly

    9. Vision Illustrations 28" and 36" LP 1" NPT CE Pipe Train Assembly Figure 9B 40" and 42" LP 1-1/2" NPT CE Pipe Train Assembly Figure 9C PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 46: Lp Vaporizer Coil Adjustment

    9. Vision Illustrations LP Vaporizer Coil Adjustment Loosen this bolt to adjust the vaporizer coil. Loosen this bolt to adjust the vaporizer coil. Figure 9D PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 47: 28" And 36" Lp/Ng 1" Npt Ce Pipe Train Assembly

    9. Vision Illustrations 28" and 36" LP/NG 1" NPT CE Pipe Train Assembly Figure 9E PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 48 9. Vision Illustrations 28" and 36" LP/NG 1" NPT CE Pipe Train Assembly (Continued) Figure 9F PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 49: Vision Fan/Heater Control Box

    Fan motor contactor COFI spark igniter Vision fan/heater control board Fan motor overload Figure 9G Top Auger Drive Check top auger drive belt tension after several hours of initial operation. Check periodically thereafter. Figure 9H PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 50: Discharge Safety Switch

    Discharge Safety Switch Metering roll speed sensor (See Figure 9J.) Discharge safety shut off switch Discharge box Figure 9I Meter Roll Speed Sensor Meter roll timing gear Meter roll speed sensor Figure 9J PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 51: Vision Upper Control Box

    Power distribution block Fan motor circuit breakers circuit breakers SCR Transformer Dryer network I/O board Terminal Main strip circuit breaker SCR Contactor and SCR Circuit board Control transformer Grounding strip circuit breakers Figure 9K PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 52: Vision Control Panel (Rear)

    9. Vision Illustrations Vision Control Panel (Rear) Display I/O board Control panel switches Figure 9L PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 53: Vision Lower Control Box (Back Panel)

    9. Vision Illustrations Vision Lower Control Box (Back Panel) Moisture control board Power supply Figure 9M PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 54: Chapter 10 Service

    The 7" meter rolls will need the meter roll pans dumped or cleared. Remove the hair pin and push the lever upward to tilt the pans as shown. This allows any grain on the pans to dump into the unload auger. (See Figure 10A on Page 55.) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 55 NOTE: If on site bearing lubrication is to be performed, see lubrication instructions for ball bearing motors. To keep motor bearings properly lubricated, and dispel any accumulation of moisture within the windings, the fan and auger motors should be operated for 15 to 30 minute each month. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 56: Lubrication Procedure

    The fan blade is secured to the motor shaft by the use of a taper-lock bushing, motor shaft key and cap screws. The size, quantity and torque of cap screws required will depend on the model of the fan. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 57: Removing The Fan Blade Assembly

    5. Align bushing and hub keyways with the key. Bushing should be flush with the end of the motor shaft. 6. Loosely install the bolts through the unthreaded holes in the bushing into the threaded holes of the hub. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 58 15. Install the grill guard and turn ON the main power source. Figure 10B Vane Axial Fan Do not exceed the torque specifications listed on the bushing bolt torque chart on Page 59 Exceeding the recommended torque will crack the fan hub. CAUTION PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 59 Cap screws installed into threaded holes to force propeller off bushing. Cap screws installed through clearance holes of bushing. (See text on Page 59 for proper torque.) Figure 10D Cap Screw Arrangement for Disassembly PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 60: Fan Motor Removal And Installation

    Lift gas assembly, straight up and remove. Orifice and other parts can now be removed. 4. Reassemble: To reassemble is reversal of disassembly: a. Ensure all parts are cleaned. b. Apply sealants in accordance with EN746-2:1998. c. Reconnect electrical connections. d. Pressure test for leaks. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 61: Metering Roll Servicing

    Attempt to release by back and forth rotation of the roll using a pipe wrench on the drive hub. If this does not release, locate the blockage and access via access doors inside the plenum. PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 62: Chapter 11 Vision Schematics And Wiring Diagrams

    11. Vision Schematics and Wiring Diagrams Fan/Heater Standard PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 63: Front Panel

    11. Vision Schematics and Wiring Diagrams Front Panel PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 64 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 65 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 66 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 67 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 68 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 69 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 70 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 71 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 72 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 73 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 74 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 75 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 76 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 77 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 78 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 79 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 80 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 81 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 82 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 83 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 84 11. Vision Schematics and Wiring Diagrams Front Panel (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 85: Upper Control Box

    11. Vision Schematics and Wiring Diagrams Upper Control Box PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 86: 380-400 Vac 3 Phase

    11. Vision Schematics and Wiring Diagrams 380-400 VAC 3 Phase PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 87: Ladder Diagram

    11. Vision Schematics and Wiring Diagrams Ladder Diagram PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 88 11. Vision Schematics and Wiring Diagrams Ladder Diagram (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 89 11. Vision Schematics and Wiring Diagrams Ladder Diagram (Continued) PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 90 NOTES PNEG-1717 CE Approved GSI/FFI Portable Dryer Manual...
  • Page 91: Chapter 12 Warranty

    14 months from arrival at port of discharge, whichever is earlier. The end-user’s sole remedy (and GSI’s only obligation) is to repair or replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in materials or workmanship.
  • Page 92 Authorities having jurisdiction should be consulted before installations are made. GSI Group 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 www.gsiag.com GSI is a worldwide brand of AGCO Corporation. Copyright © 2014 by GSI Group Printed in the USA CN-310824...