Manual Version 10/2004 sirius Safety Relays 3TK2845...
Page 3
Information, Contents Product Description Technical Data Safety Switchgear Mounting, Wiring, 3TK2845 Multifunction Initial Start-up Device Applications Manual Order No.: 3TK2890-0A (German) Order No.: 3TK2890-0B (English) Version 10/2004 GWA 4NEB 926 2087-02...
Page 4
This product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended. Copyright Siemens AG 2004 All rights reserved Disclaimer of liability The reproduction, transmission or use of this document or its con- We have checked this manual to ensure that its contents are correct tents is not permitted without express written authority.
Page 7
Tables Table 1-1: Description of symbols ......Table 1-2: Order numbers of the various device versions ....Table 3-1: Operating status of the 3TK2845-.BB40 .
Page 9
Important Information Important Information Purpose of manual The information contained in this manual is designed to assist you in configuring safety-related features as part of an entire system or machine. Readers This manual applies to persons who possess the necessary qualifications for commissioning and operating 3TK2845 multifunction devices.
Page 10
It is the responsibility of the manufacture to ensure that the systems and machines function reliably. Siemens AG, its branch offices and subsidiaries (referred to as “Siemens” in the following) cannot guarantee all of the proper- ties of an entire system or machine that was not designed specifically by Sie- mens.
Product Description 3TK2845 Multifunction Device Fig. 1-1: Device versions Functions The 3TK2845 multifunction device is used to implement safety-related functions (i.e. EMERGENY STOP monitoring, protective door monitoring) and monitoring functions using non-contact protective equipment (BWS), such as light curtains and safety mats, in machines with movable components. The device is especially suitable for the use at –...
Product Description Device Versions 3TK2845 multifunction devices are available in two versions: 1. Stop Category 0: All outputs switch off without delay. 2. Stop Category 0+1: Output I and II switch off without delay, output III and IV switch off with a time delay. 1.4.1 3TK2845-.BB40 Multifunction Device (Stop Category 0) Standard operation...
Product Description 1.4.2 3TK2845-.BB41/-.BB42/-.BB44 Multi-Function Devices (Stop Category0+1) Standard operation Sensor block D is inactive during standard opera- tion (key-operated switch OFF). When using a sensor at sensor blocks A to C, output blocks I and II switch off safely without delay and III and IV switch off with a time delay.
Page 18
Technical Data Technical Data Type 3TK2845-..Specifications EN60204-1, EN292, EN954-1, IEC 61508 Category according to EN954-1 Safety Integrity Level (SIL) SIL 3 Test certifications TÜV Rated insulation voltage U 300 V Rated impulse withstand voltage U 4 kV Rated supply voltage U 24 V DC Operating range 0.85 to1.15 U...
Technical Data Rated operational currents I per IEC 60 947-5-1 Utilization Rated operating Rated operational Terminal(s) category voltage U current I 13, 14; 33, 34; 37, 38 DC-13 24 V 1.0 A 13, 14; 33, 34; 37, 38 DC-13 230 V 0.1 A 13, 14;...
Technical Data Dimension Drawings 3TK2845-.BB41/-.BB42/-.BB44 3TK2845-.BB40 Y11 Y12 Y35 Y21 Y22 Y 11 Y 12 Y 35 Y 21 Y 22 A(+) Y41 Y42 Y65 A(+) Y41 Y42 Y65 POWER POWER RUN 1 RUN 1 RUN 2 RUN 2 FAULT FAULT 13 14 24 Y72 Y82 A2(-) 13 14 24 Y72 Y82...
Page 22
Mounting, Wiring, Initial Start-up Warning Dangerous electrical voltage! Can result in electrical shock and burns. Shut off all electricity prior to working on the system and device. Warning Depending on the ambient conditions, the devices must be installed in switch- gear cabinets exhibiting degree of protection IP23, IP43 or IP54 respectively.
Mounting, Wiring, Initial Start-up Mounting The 3TK2845 multi-function device is designed for snap-on mounting on a 35 mm standard mounting rail complying with EN 50 022. 3RP1902 Fig. 3-1: 3TK2845 multifunction device for snap-on mounting The device can also be mounted using screws and two additional plug-in lugs each.
Mounting, Wiring, Initial Start-up Wiring The 3TK2845 multifunction device is available either with screw terminals or spring-loaded terminals. Please refer to the table below for the required terminal cross sections and maximum permissible torques. 3TK2845-1... 3TK2845-2... M3,5 0,8 to 1,2 Nm —...
Mounting, Wiring, Initial Start-up Initial Start-up The 3TK2845 multifunction device is ready for operation after the power supply is connected at terminals A1 and A2. The device runs a self-test during which the proper functionality of the internal electronics is checked. The internal circuit elements are cyclically monitored for faults during operation.
Mounting, Wiring, Initial Start-up Operating status of the 3TK2845-.BB41/-.BB42/-.BB44 LEDs Description POWER Power supply voltage exists Power supply voltage missing RUN 1 Output block I or II active Output blocks I and II not active RUN 2 Output block III or IV active Output blocks III and IV not active Output blocks III and/or IV, time delay running FAULT...
Mounting, Wiring, Initial Start-up Fault Codes Fault Cause Action FAULT LED blinks Circuitry changed during operation Check wiring at terminals Y35, Y65 with CODE 40 and restart 3TK2845 FAULT LED blinks Feedback loop not closed i.e. moni- Troubleshoot fault and restart with CODE 81 tored contactor welded or feedback 3TK2845...
Applications Commonly used applications are listed in the following chapter. All of these functions can be performed using the 3TK2845 multifunction device. The advan- tage of using this device is the fact that several safety-related functions i.e. pro- tective door monitoring and monitoring using non-contact protective equipment (BWS) such as light curtains and safety mats can be implemented using only one 3TK2845 multifunction device, rather than using several safety combina- tions.
Applications Switching Examples A.1.1 EMERGENCY STOP monitoring; light grid monitoring; key-operated switch for deactivating the light grid during maintenance Stop Category 0; Type 4 (EN 61496-1)/Category 4 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic; 24 V DC Main EMERGENCY STOP 3TK2841...
Applications A.1.2 EMERGENCY STOP monitoring; protective door monitoring; key-operated switch for deactivating the protective door during maintenance Stop Category 0; Category 4 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 Signaling output, electronic; 24 V DC L+(24V DC) Y64 52 K1-K4...
Page 32
Applications A.1.3 EMERGENCY STOP monitoring; protective door monitoring; key-operated switch for deactivating the protective door during maintenance Stop Category 0; Category 2 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic; 24 V DC L+(24V DC) Y64 52 K1-K4...
Applications A.1.4 EMERGENCY STOP monitoring; protective door monitoring; key-operated switch for deactivating the protective door during maintenance; frequency converter (FC) operation Stop Cat 0 and 1; Cat. 4 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic;...
Applications A.1.5 EMERGENCY STOP monitoring; protective door monitoring; key-operated switch for deactivating the protective door during maintenance; frequency converter (FC) operation Stop Cat 0 and 1; Cat. 2 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic;...
Applications A.1.6 EMERGENCY STOP monitoring; light grid monitoring; key-operated switch for deactivating the light grid during maintenance; frequency converter (FC) operation Stop Cat 0 and 1; Type 4 (EN 61496-1)/Cat. 4 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic;...
Applications A.1.7 EMERGENCY STOP monitoring; protective door monitoring; key-operated switch for deactivating the protective door during maintenance; releasing the protective door; frequency converter (FC) operation Stop Cat 0 and 1; Cat. 4 (EN954-1); 2 NO contacts, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic;...
Page 37
Applications A.1.8 EMERGENCY STOP monitoring; protective door monitoring; key-operated switch for deactivating the protective door during maintenance; releasing the protective door; frequency converter (FC) operation Stop Cat 0 and 1; Cat. 2 (EN954-1); 2 NO contact, electronic; 2 NO contacts, as floating release contacts; 1 signaling output, electronic;...
Page 39
Sender (please complete) Name Company/Department SIEMENS AG A&D CD MM 3 Address P .O Box 1954 92220 Amberg, Germany Telephone No. Fax: +49 (0) 9621 / 80-3337 Manual for Safety Switchgear 3TK2845 Multifunction Device Did you come across any mistakes while reading this manual? Please inform us about these mistakes by indicating them on the form provided.
Page 42
Siemens Aktiengesellschaft Automation and Drives Low Voltage Controls and Distribution Postfach 32 40 D-91050 Erlangen Bestell-Nr.: 3TK2890-0B w w w . s i e m e n s . c o m / s i r i u s...