Danfoss VLT HVAC Drive Metasys N2 Manual page 9

Hide thumbs Also See for VLT HVAC Drive Metasys N2:
Table of Contents

Advertisement

®
VLT
HVAC Drive Metasys N2
2.1.7. Analog Input Commands (Acknowledged)
VLT Re-
sponse
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK, no ac-
tion
ACK, no ac-
tion
ACK, no ac-
tion
Table 2.2: No Error code in this table.
Sub-
Com-
Re-
NPA Object
com-
mand
gion
no.
mand
1
-
1
0-23
1
-
1
0-23
1
-
1
0-23
1
-
1
0-23
1
-
1
0-23
1
-
1
0-23
1
-
1
0-23
1
-
1
0-23
2
-
1
0-23
2
-
1
0-23
2
-
1
0-23
2
-
1
0-23
2
-
1
0-23
2
-
1
0-23
7
2
1
0-23
7
3
1
0-23
7
7
1
0-23
MG.11.G1.02 - VLT
®
is a registered Danfoss trademark
Attrib-
Attribute Message
ute No.
Type
Read Analog
1
Byte
Input
Read Analog
2
Byte
Input
Read Analog
3
Float
Input
Read Analog
8
Float
Input
Read Analog
9
Float
Input
Read Analog
10
Float
Input
Read Analog
11
Float
Input
Read Analog
12
Float
Input
Write Analog
1
Byte
Input
Write Analog
8
Float
Input
Write Analog
9
Float
Input
Write Analog
10
Float
Input
Write Analog
11
Float
Input
Write Analog
12
Float
Input
Override Ana-
-
Float
log inputs
Override Ana-
-
-
log Release
Write Analog
-
-
Input Attributes
2. Instructions
Comments
Read Object Configura-
tion attribute associ-
ated with each individ-
ual point
1)
Read Object Status
attribute associated
with each individual
point
2)
Read Analog Input
Value attribute associ-
ated with each individ-
ual point
Read Low Alarm attrib-
ute associated with
each individual point
Read Low Warning at-
tribute associated with
each individual point
Read High Warning at-
tribute associated with
each individual point
Read High Alarm attrib-
ute associated with
each individual point
Read Differential attrib-
ute associated with
each individual point
Write to Object Config-
uration attribute associ-
ated with each individ-
ual point
Write to Low Alarm Lim-
it attribute associated
with each individual
point
Write to Low Warning
Limit attribute associ-
ated with each individ-
ual point
Write to High Warning
Limitattribute associ-
ated with each individ-
ual point
Write to High Alarm
Limit attribute associ-
ated with each individ-
ual point
Write to Differential at-
tribute associated with
each individual point
Analog inputs are "out-
puts" from the frequen-
cy converter and should
not be written over by
the network controller
Analog inputs are "out-
puts" from the frequen-
cy converter and should
not be written over by
the network controller
Optional command for
slave devices. Only
used for N2 commis-
sioning purposes
9