Replacement Parts; Disposal Note; Fault / Cause / Remedy - Grohe Eurosmart Cosmopolitan E 36 325 Manual

Hide thumbs Also See for Eurosmart Cosmopolitan E 36 325:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
V. Mixer spindle, see fold-out pages II and III
1. Disconnect fitting from connections.
2. Remove fitting from wash basin.
Disassembly is as described in section "Setting temperature
limiter", see Fig. [9] or [11].
3. Pull out mixer spindle and replace, see Fig. [19].
Assemble in reverse order.

Fault / Cause / Remedy

Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve without
contact
• No voltage
- Battery discharged
- Power supply unit defective
- Plug-in connector without contact
- Power supply switched off
• Hands not in detection zone
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
• Shut-off valves, service valves not fully open
• Water supply restricted

Replacement parts

see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

Disposal note

Dispose of batteries in accordance with national
regulations.
Remedy
- Open shut-off valves, service valves
- Clean filter
- Replace solenoid valve
- Attach plug-in connector
- Replace battery
- Replace power supply unit
- Check plug-in connectors
- Switch on voltage supply
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control (special
accessory, prod. no.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Fully open shut-off valves, service valves
- Check supply lines, open shut-off valves,
service valves
8

Hide quick links:

Advertisement

Table of Contents
loading