Safety Notes; Technical Data; Temperature Adjustment; Replacement Parts - Grohe EUROSMART COSMOPOLITAN E 36 334 Manual

Hide thumbs Also See for EUROSMART COSMOPOLITAN E 36 334:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
GB

Safety notes

Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.

Technical data

Fitting with switched-mode power supply:
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
Fitting with battery:
• Voltage supply:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
• Type of fitting protection:
Thermal disinfection possible.
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
• Solenoid valve defective
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
Mixing device
• See "Flow rate too low"
incorrect (36 336)
• Limescale on mixer spindle
2.4 W
6V lithium battery type CR-P2
60 s
1 s
12cm
IP 59K
A
2
2500 V
100 °C
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply!
Installation
, see fold-out page II.
Plaster and tile the wall, excluding the area of the
structural shell protection.
Flush pipes thoroughly before and after installation
(observe EN 806)!
Open hot and cold water supply and check that
connections are watertight.

Temperature adjustment,

see fold-out page II.
Operation,
see technical product information, 99.0438.xxx.
Maintenance
, see fold-out page II.
•Shut off hot and cold water supply.
•Disconnect voltage supply.
•Inspect and clean all components and replace if
necessary.

Replacement parts

see fold-out page I (* = special accessories)
,
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Clean or replace mixer spindle
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eurosmart cosmopolitan e 36 335