Winch mount

Advertisement

WIRING INSTRUCTIONS:
1. To make routing wires and installing your
contactor easier, temporarily reposition the
coolant overflow tank by lifting/pulling it up to
pop it out of its hanging bracket.(see Figure 11)
2. Mount Contactor. See Figure 11 & 12 for
suggested location. Mark holes out and drill.
Attach contactor using hardware supplied with
your winch.
3. Rocker Switch - red/power wire-
-Unclip the fuse panel from the body (see Figure
11 & 14 for location). Locate the White wire with
Black stripe next to the heavy red power wire as
shown in Figure 13. Note: The ignition controlled
accessory wire may be red with a black stripe on
some machines. Verify you have the correct wire by
using a test light. Test light should only illuminate
when key is on.
-Connect the red wire from your rocker switch to the
white with black stripe ignition controlled accessory
wire using the supplied quick connector or other
means. (as shown in Figure 13)
4. Use the wiring instructions in your winch manual
and finish wiring accordingly.
©2015 Copyright Kappers Fabricating, Inc. All rights reserved
Fuse Panel
"Figure 11" Coolant overflow tank location & suggested
contactor location
"Figure 12" Contactor installation
Red Wire
"Figure 13" Accessory wire location
Fuse Panel
"Figure 14" Winch cables routed to contactor
Coolant Overflow
Tank
White / Black wire
Red / Black wire
Access
Hole
4