Fittings and installations,
10
continued
Step
7
Mount the front
door again
8
Make a water trap which meets the measurements on the picture and pour wa-
ter in it. Alternatively you can use the water trap from Dantherm (accessories):
9
Connect the hose to the drain – The drain pipe must be kept frost proof all the
way, to ensure that the water can run unhindered.
The drain pipe must at least fall by 1 % all the way from the unit to the drain
outlet.
10
Dantherm A/S recommends insulated flex ducts when connecting to connect-
ors/coupling connectors. The ducts must be completely stretched to avoid un-
necessary loss of pressure.
Make sure you connect the ducts to the right connectors: The ducts must not
"hang" from the unit without support.
Dantherm recommends that the ducts are mounted with a flexible hose con-
nection, to make the connection easier and to damp noise and vibrations from
the installation.
HCH 5
HCH 8
Action
Continued overleaf