Section 13. Electrical - Low Voltage

13.1 Low Voltage Maximum Wire Length
Table 11.1 defines the maximum total length of low
voltage wiring from the outdoor unit, to the indoor
unit, and to the thermostat.
13.2 Low Voltage Hook-up Instructions
STEP 1 - Route control wiring to unit. Remove the
external sheathing of the wiring approximately 5".
Note: Optional Low Voltage Conduit
Entry Kit number BAYLVKIT100A is
available.
STEP 2 - Remove Coil panel by turning the Phillips
head door fasteners, rotating the door away from the
cabinet, and removing.
Table 11.1
24 VOLTS
WIRE SIZE
MAX. WIRE LENGTH
18 AWG
150 Ft.
16 AWG
225 Ft.
14 AWG
300 Ft.
5"
27