Refilling combination with softening cartridge
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
Only fasten the plastic sealing plugs by hand (without
tools)
1.
Thoroughly flush pipework
2.
Install the refilling combination (see NK300S)
3.
Install in horizontal pipework with discharge
connection directed downwards
• Note flow direction (indicated by arrow)
• Install in horizontal pipework with discharge
connection directed downwards
• Installation height should be min. 55cm from the
floor in order to warrant safe replacement of the
cartridge
4.
Attach drain pipe to discharge connection (plastic pipe
HT 50)
5.
Install heater water treatment unit (VE300S) directly
below the refilling combination (NK300S) and secure
in place with the wall bracket
• Install in horizontal pipeline
• Note flow direction (indicated by arrow)
• Install without tension or bending stresses
6.
Screw the complete demineralisation cartridge
(P300LES) into the heater water treatment unit
(VE300) and tighten by hand.
4

Start-up

For information on start-up, see the instructions of the
individual components (included in scope of delivery)
1.
Adjust the back pressure (see NK300S)
2.
Set to complete demineralisation (see VE300S)
3.
Fill the system (see VE300S)
5

Maintenance

In order to comply with EN 806-5, water fixtures must
be inspected and serviced on an annual basis.
As all maintenance work must be carried out by an
installation company, it is recommended that a
servicing contract should be taken out.
In accordance with EN 806-5, the following measures must
be taken:
5.1 Inspection
For information on inspections, see the instructions of
the individual components (included in scope of
delivery)
1.
Pressure reducing valve function control (see
NK300S)
2.
Drain valve function control (see NK300S)
GB
5.2 Maintenance
Do not use any cleansers that contain solvents and/or
alcohol for cleaning the plastic parts, because this can
cause damage to the plastic components - water
damage could result.
Detergents must not be allowed to enter the
environment or the sewerage system!
For information on maintenance, please refer to the
instructions of the individual components (included in
scope of delivery)
1.
Valve insert and screen (see NK300S)
2.
Maintenance and cleaning of cartridge insert
(see NK300S)
3.
Check valve (see NK300S)
4.
Replacement of the complete demineralisation
cartridge (see VE300S)
To determine the maximum capacity of the complete
demineralisation cartridge, see instruction P300L
6

Disposal

For information on malfunctions / trouble shooting, please
refer to the instructions of the individual components
(included in scope of delivery)
Observe the local requirements regarding correct waste
recycling/disposal!
7

Troubleshooting

For information on malfunctions / trouble shooting,
please refer to the instructions of the individual
components (included in scope of delivery)
8

Spare Parts

For Spare Parts visit homecomfort.resideo.com/europe
9

Accessories

For Accessories visit homecomfort.resideo.com/europe
4
MU1H-1561GE23 R0420

Advertisement

Table of Contents
loading

This manual is also suitable for:

Braukmann nk300se-ve-1/2aBraukmann nk300se-s0