Advertisement

[33] Access Code Group A Assignment
Default
On
Zone Light 1
On
Zone Light 2
On
Zone Light 3
On
Zone Light 4
On
Zone Light 5
On
Zone Light 6
On
Zone Light 7
On
Zone Light 8
[34] Access Code Group B Assignment
Default
On
Zone Light 1
On
Zone Light 2
On
Zone Light 3
On
Zone Light 4
On
Zone Light 5
On
Zone Light 6
On
Zone Light 7
On
Zone Light 8
[35] Communicator Call Direction Options
Default
1
Zones Group A Alarms and Restorals
1
Zones Group B Alarms and Restorals
1
Access Codes Group A Openings and Closings
1
Access Codes Group B Openings and Closings
1
Priority Alarms and Restorals
1
Maintenance Alarms and Restorals
Enter:
[0] No transmissions for this group
[1] Call 1st phone number back up to 2nd (becomes 1st number only, when section [15] item [7] is on)
[2] Call 2nd phone number only
[3] Always call both phone numbers
[36] Software Reset EEPROM Memory to Factory Defaults
[37] Through [45] Reserved for Future Use
Page 23
Note:
If zone light is on that access code is assigned
to Group A.
Access codes 9 through 16 are permanently assigned
to Group A.
If zone light is on in sections [33] and [34], the code is
common to both sides and will arm or disarm the entire
system.
Page 23
If zone light is on, that access code is assigned
Note:
to Group B.
If light is on in sections [33] and [34], the code is
common to both sides and will arm or disarm the entire
system.