Set Conf
Activates or deactivates the flashing light/beep acknowledgement.
If the flashing light is to flash briefly when the system is armed or disarmed, use the alarm
panel to enable the "Strobe on Set" or "Strobe on Unset" option in the relevant partition.
If the sounder is to beep briefly when the system is armed or disarmed, use the alarm panel
to enable the "Beep on Set" or "Beep on Unset" option in the relevant partition.
Installer Mode -> Partitions -> Partition x -> All set / Part set
Jumper connected = flashing light/beep activated
Jumper open
If the jumper is not connected, the sounder ignores the "Strobe on Set", "Strobe on Unset",
"Beep on Set" and "Beep on Unset" commands from the alarm panel. The alarm panel
sends the commands to all the sounders in the same partition. You can thus only connect
the jumpers in certain sounders and not in others.
Note:
Only use the "Strobe on Set", "Strobe on Unset", "Beep on Set" and "Beep on Unset"
options if absolutely necessary. If fewer commands need to be processed, this can have a
positive impact on the general performance of the system.
Jam Det
If a jumper is set to "Jam Det" (jamming detection, jamming monitoring), the sounder
monitors potential attempts to jam the wireless signal to the alarm panel. If signal jamming
is detected, the message "Signal jamming" is sent to the alarm panel. The alarm panel can
then activate the sounder, depending on the setting.
Note:
This function is not covered by the INCERT certification.
Note:
The option
Installer Mode -> System -> Security -> Jamming
can be set to "Blocked", "Fault" or "Tamper". If you select "Blocked", signal jamming is
not reported. You can find further information on this in the Technical Manual for the
alarm panel.
Alarm panels, sounders and special components can monitor signal jamming independently
of each other.
Tone
Set the desired normal alarm tone. Two sounders that are placed in direct proximity to one
another can thus be distinguished from one another acoustically.
Jumper connected = Normal alarm tone 1
Jumper open
= flashing light/beep deactivated
= Normal alarm tone 2
Functions, jumpers and displays
47 |