6. Maintenance

Important!
Always disconnect from the mains before doing
any maintenance or repair work.
To maintain the high-pressure cleaner in perfect
working order, the intake filter must be checked
and cleaned after every 50 hours of operation.
6a
If the machine has not been used for a long time,
it may be furred up inside. Unblock the motor
with a screwdriver inserted in the borehole at the
rear.
6b
Then remove the key and proceed to start up the
high-pressure cleaner.
14
06.11.2001 14:00 Uhr
6c
6d
Seite 14
Clean the nozzle head using the cleaner
supplied. After dismantling the lance (Fig. 6c),
remove any dirt from the borehole on the head
(Fig. 6d) and rinse thoroughly.