Troubleshooting
Code
Message
P474
Grid L3 DC Offset
Current
P500
PV Insulation
Resistance
P501
Inverter Over Temp.
P502
PV Over Temp.
P503
Batt Over Temp.
P504
DC Link Over Voltage
P505
DC Link Over Voltage
Unbalance
4
P506
PVA Over Voltage
P507
PVB Over Voltage
P508
Batt A Over Voltage
P509
PVC Over Voltage
P510
Batt B Over Voltage
P511
DC link Top Over
Voltage
P512
DC link Bottom Over
Voltage
P513
DC link Total under
Voltage
P514
Batt B Over Current
Instant
Description
DC offset current is added on
grid(L3)
Insulation resistance level on PV is
lower than the limitation
The inverter IGBT temperature is
higher than the limitation
The PV IGBT temperature is higher
than the limitation
The battery IGBT temperature is
higher than the limitation
Voltage level of the DC Link is
higher than the limitation
Voltage level of the DC Link
balance is higher than the
limitation
Voltage level of PV A is higher
than the limitation
Voltage level of PV B is higher
than the limitation
Voltage level of battery A is higher
than the limitation
Voltage level of PV C is higher
than the limitation
Voltage level of battery B is higher
than the limitation
Voltage level of the DC Link Top is
higher than the limitation
Voltage level of the DC Link
Bottom is higher than the
limitation
Voltage level of the DC Link total
is lower than the limitation
Current level of the battery B is
instantaneously higher than the
limitation
Solution
Automatically restart after
detecting fault
Automatically restart after
PV IR is normal
Automatically restart after
INV temp is normal
Automatically restart after
PV temp is normal
Automatically restart after
Battery temp is normal
Automatically restart after
DC Link voltage is normal
Automatically restart after
DC Link voltage is normal
Automatically restart after
PV A voltage is normal
Automatically restart after
PV B voltage is normal
Automatically restart after
Battery A voltage is normal
Automatically restart after
PV C voltage is normal
Automatically restart after
Battery B voltage is normal
Automatically restart after
DC Link voltage is normal
Automatically restart after
DC Link voltage is normal
Automatically restart after
DC Link voltage is normal
Automatically restart
after Battery B Current is
normal