Troubleshooting

Error Codes and Messages

PCS Error Codes

y Do not leave the ESS in the Fault standby state for a long time because of the battery discharge
may occur during the long standby state.
y If the battery fault occurs immediately after starting PCS it means Battery failure. Check the
battery SOC also voltage and fault information, and turn off the power of the ESS until service
action is taken.
y If the battery SOC is low the battery may charge from the grid for self-protection. (Emergency
Charging) This function is to prevent shutdown of the ESS, deep discharge and failure of the
Battery. An Emergency Charge is not an ESS fault.
Code
Message
P400
AC MisWiring Fault
4
P401
Meter Comm Fault
P403
BMS A Comm. Fault
P404
PMS Comm Fault
P405
SDSP Comm Fault
P406
SDSP Fault
P407
Fan Fault
P408
Grid Relay Fault
P411
Battery A MisWiring
Fault
P413
BMS B Comm. Fault
Description
Incorrect wiring grid connection
has detected
Communication error with the
energy meter
Communication error with the
connected battery for over 30
seconds.
Communication error with the
connected PMS for over 60
seconds.
Communication error with the
processing unit for over 60
seconds
P540(SDSP Detection) occurs 3
times
P541, P542 (Fan Detection)
occurs 3 times
Fault occurs 3 times in the same
relay
Battery 1 power line connection is
abnormal
Communication error with the
connected battery for over 30
seconds.
Solution
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center
Contact service center

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ess home 8D010ke1n211D008ke1n211

Table of Contents