Summary of Contents for Adeunis RF sigfox RC4 PULSE V3

  • Page 1 RC4 PULSE V3 Transceiver pulse interfaces User Guide Version 1.0.0 Adeunis 283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France www.adeunis.com...
  • Page 2 RC4 PULSE V3 - User guide version NEW DOCUMENTATION ENGLISH • Dedicated to a product • Cautions & electrical warnings USER GUIDE • Declaration of conformity • Product functionalities and modes • Casing dimensions • Characteristics (casing and electrical) •...
  • Page 3: Préambule / Preamble / Präambel / Preambolo / Preámbulo

    RC4 PULSE V3 - User guide version Préambule / Preamble / Präambel / Preambolo / Preámbulo • Ce guide décrit les fonctionnalités du produit adeunis®. Il explique les modes de fonctionnement du produit et la manière de le confi gurer.
  • Page 4 RC4 PULSE V3 - User guide version Table of content New documentation PRODUCTS AND REGULATORY INFORMATION PRODUCT PRESENTATION 1.1. General description 1.2. Dimensions 1.3. Electronic card 1.4. Technical Specifications 1.4.1 General characteristics 1.4.2 Autonomy 1.4.3 Sensor compatibility 1.4.4 Physical interface characteristics 1.4.4.01 INPUT Circuit...
  • Page 5: Products And Regulatory Information

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 PRODUCTS AND REGULATORY INFORMATION Document Information Title sigfox RC4 PULSE V3 - User Guide Document type User Guide Version 1.0.0 This document applies to the following products :...
  • Page 6: Declaration Of Conformity - Australia

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 Declaration of conformity - Australia Manufacturer’s name : adeunis. Manufacturer’s address : Parc Technologique PRE ROUX 283 rue Louis NEEL 38920 CROLLES Country: FRANCE Authorized representative M2M Connectivity Pty Ltd...
  • Page 7 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 Declaration of conformity - New Zealand Manufacturer’s name : adeunis. Manufacturer’s address : Parc Technologique PRE ROUX 283 rue Louis NEEL 38920 CROLLES FRANCE Country: Authorized representative Direct Control Limited...
  • Page 8 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 INTRODUCTION All rights to this manual are the exclusive property of adeunis®. All rights reserved. Copying this manual (wit- hout written permission from the owner) via printing, copying, recording or by any other means, translating this manual (in full or partially) into any other language, including all programming languages, using any electrical, mechanical, magnetic or optical devices, manually or any by other methods, is prohibited.
  • Page 9: Environmental Recommendations

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 ENVIRONMENTAL RECOMMENDATIONS All superfl uous packaging materials have been eliminated. We have done everything possible to make it easy to separate the packaging into three types of materials: cardboard (box), expanded polystyrene (fi ller material) and polyethylene (packets, foam protective sheets).
  • Page 10: Recommandations Regarding Use

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 RECOMMANDATIONS REGARDING USE • Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it doesn’t, please consult your supplier.
  • Page 11: General Description

    IMPORTANT NOTE: the SIGFOX PULSE can only be started or restarted using a magnet. Description • sigfox RC4 PULSE V3 is a ready to use radio transmitter that can be used to transform any type of meter into a wireless meter (smart meter). •...
  • Page 12 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 1.2. Dimensions Values in millimeters 1.3. Electronic card Internal antenna RF module Internal battery sigfox protocol USB port for product configuration Screw terminals for connecting meters Page of 27...
  • Page 13: Technical Specifications

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 1.4. Technical Specifications 1.4.1 General characteristics Settings Value Supply voltage Nominal 3.6V Power supply Battery Li-SOCl2 Maximum Power 90mA Working temperature -25°C+70°C Dimensions 105 x 50 x 27mm...
  • Page 14 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 1.4.4 Physical interface characteristics 1.4.4.01 INPUT Circuit The schematic diagram is the following: Absolute maximum ratings Unit Minimum input voltage - 0.7 Maximum input voltage Electrical characteristics (Typ.)
  • Page 15: Global Operation

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 2. PRODUCT OPERATION 2.1. Global Operation Important: adeunis® use the most significant byte first format. The product has several operating modes: PARK MODE Presence of a magnet on the product >6s...
  • Page 16: Application Operation

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 2.2. Application operation 2.2.1 Periodic transmission The product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram: Product in standby...
  • Page 17 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 2.2.2 Periodic transmission with history The product allows the accumulation of several successive meter values before the periodic transmission of the set of values according to the following scheme:...
  • Page 18 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 2.2.3 Periodic transmission with redundancy The product enables to ad redundancy in the frame with historisation (cf scheme here under). Thanks to redundancy the product will memorize a certain number of data and send them again in the next frame.
  • Page 19 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 2.2.4 Flow threshold alarm transmission The product allows the detection of the exceeding of a flow threshold for each counting entry according to the following scheme: Product in standby...
  • Page 20 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 The settings associated with this mode of operation are: • Enabling and Configuring inputs (register 320) • History configuration (register S321) • Anti-bounce timer period (register S322) •...
  • Page 21 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 Register Value encoding Value Result S320 Hexadecimal 0x39 Channel A : • Activated • Meter other than gas • Tamper input activated Channel B : • Activated •...
  • Page 22 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 2.2.7 Leaks detection Product in standby Flow calcu- Pulse detec- Period of lation period ted and 24h reached reached ? validated Counting Calculation of flow Value pulse of the counter of zero flow period <(counter...
  • Page 23 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 Example : Register Value encoding Value Result S320 Hexadecimal 0x39 Channel A : • Activated • Meter other than gas • Tamper input activated Channel B : •...
  • Page 24: Configuration And Installation

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 REGISTERS AND FRAME DESCRIPTION To know the content of the registers and of each frames (uplink and downlink) of the product, refers to the TECHNICAL REFERENCE MANUAL of the TEMP product, available on the adeunis website: https://www.adeunis.com/en/produit/pulse-impulse-interface/...
  • Page 25 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 5.3. Mounting the counters on the screw terminals Once the nut and packing seal are installed, the strands of the meter cable can be connected to the screw terminals of the product.
  • Page 26 RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 Meter with 3-wire output GROUND / GND GND / Brown IMPULSE_1 / BF IMPULSE_1 / White TAMPER TAMPER_1 / Green In this configuration, it is preferred to activate input TAMPER of A-channel (register 320 bit 3 = 1) and deactivate B-channel (register 320 bit 4=0) which is not no used.
  • Page 27: Document History

    RC4 PULSE V3 - Guide utilisateur / User guide version V1.0.0 5.4. 6 wires cable version A version of the PULSE is proposed with a 6 wires cable of 70 cm already linked to the terminal blocks. Here under the explanations of the colors:...