Download Print this page

CyberData 011472 Installation Quick Reference

Informacast enabled ip66 outdoor horn
Hide thumbs Also See for 011472:

Advertisement

Quick Links

RTFM Switch
RTFM Access
The RTFM switch access will be on the top side of the horn hidden under a screw that will be used to keep the unit
secured. To access the RTFM, complete the following steps:
1. Remove the screw to gain access to the RTFM button (see the figure below).
2. Use a paper clip to feed through the hole to press the RTFM button (see the figure below).
Announce the IP Address
To broadcast the device's current IP address, press and hold the RTFM switch for a couple of seconds and then release
it.
Restore the Factory Default Settings
To restore the factory defaults, complete the following steps:
1. Press and hold the RTFM switch until you hear the device announce the words, "restoring defaults" and "rebooting".
2. Release the RTFM switch. The device will be restored to the factory default settings.
Cover
Screw
RTFM
Access
Contacting CyberData
Corporate Headquarters
Sales: (831) 373-2601 ext. 334
CyberData Corporation
Support: 831-373-2601 ext. 333
3 Justin Court
Support Website:
Monterey, CA 93940, USA
RMA Department: (831) 373-2601 ext. 136
Phone: 831-373-2601
RMA Email: RMA@CyberData.net
Fax: 831-373-4193
RMA Status:
http://www.cyberdata.net/
Warranty Information:
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
Paper Clip
RTFM
Access
http://support.cyberdata.net/
http://support.cyberdata.net/
http://support.cyberdata.net/
931511E
Quick Reference
The IP Endpoint Company
Typical System Installation
1.0" [25 mm]
Getting Started
Download the Operations Guide PDF file from the Documents tab at the following webpage:
https://www.cyberdata.net/products/011472
Create a plan for the locations of your paging amplifiers.
WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
WARNING: The InformaCast Enabled IP66 Outdoor Horn enclosure is not rated for any AC voltages!
Parts
Quick Reference
Installation Quick Reference
InformaCast Enabled IP66 Outdoor Horn
011472
Parameter
Factory Default Setting
IP Addressing
DHCP
a
IP Address
10.10.10.10
Web Access Username
admin
Web Access Password
admin
a
Subnet Mask
255.0.0.0
a
Default Gateway
10.0.0.1
a. Default if there is not a DHCP server present.
Compliant Non-PoE Ethernet Switch
InformaCast Enabled
VoIP Phone
IP66 Outdoor Horn
(1) Assembly
931511E
© 2019, CyberData Corporation, ALL RIGHTS RESERVED
*See the Operations Guide for more
installation options.
InformaCast Server

Advertisement

loading
Need help?

Need help?

Do you have a question about the 011472 and is the answer not in the manual?

Questions and answers

Summary of Contents for CyberData 011472

  • Page 1 RMA Department: (831) 373-2601 ext. 136 Phone: 831-373-2601 RMA Email: RMA@CyberData.net Fax: 831-373-4193 RMA Status: http://support.cyberdata.net/ http://www.cyberdata.net/ Warranty Information: http://support.cyberdata.net/ © 2019, CyberData Corporation, ALL RIGHTS RESERVED 931511E Quick Reference Quick Reference 931511E © 2019, CyberData Corporation, ALL RIGHTS RESERVED...
  • Page 2 Status LED DIMENSIONS ARE IN INCHES [MILLIMETERS] 2.008 [51] With screws, dimensions 4.016 [102] are approximate. © 2019, CyberData Corporation, ALL RIGHTS RESERVED 931511E Quick Reference Quick Reference 931511E © 2019, CyberData Corporation, ALL RIGHTS RESERVED...