  • Page 1 BL30 DE EN FR IT NL PT PL RU DA FI NO SV BEDIENUNGSANLEITUNG OPERATING MANUAL MANUEL D'UTILISATION...
  • Page 2 This document has been prepared with the appropriate care. We can accept no liability for any errors or omissions.© TROTEC® circuitry of the appliance. This physical effect, 1.
  • Page 3 m Make sure that the data logger is always used/ 5. Alarm when exceeding/falling below user-defined li- stored in an upright position. This also applies mit values after measurements taken at low temperatures 6. Including analysis software for the purpose of graphi- or in highly humid environments.
  • Page 4 Resolution: .....0.1% R.H., 0.1°C Temperature Measurement range -40 to +70°C (-40 to Memory space: ... . 32,700 measured values +158°F) Measuring cycle: .
  • Page 5 The yellow LED indicates that the relative humidity maximum or minimum values stored during the has exceeded/fallen below the user-defined limit values. recording period. The appliances returns to measu B - 4 opera ting instr uctions - clima te da t a logger Bl30...
  • Page 6 Software applications: 15. The message „-LO-“ indicates that the sensor for the temperature and humidity is not correctly connected. You can transfer the collected measured data to your In this case, you can proceed as follows: Open the back PC with the data logger‘s USB software. The program of the appliance and connect the sensor correctly.
  • Page 7 Main menu Print: prints out the graph or list Help Save: To save the collected data on the hard Reset time and date disk Click on the icon in order to reset the time and date. A new Open: To open a stored file window appears.
  • Page 8 • You can set the measurement sampling rate for the • By clicking „Circulating Record“ or „No Circulating“, data logger with the field „Samprate setup“. Enter the you can decide whether the stored data should be desired number in the left-hand box and the unit of overwritten (Circulating Record) when the memory time in the right-hand box.
  • Page 9 tended measurement. Therefore we strongly After successful transmission of the data, a window ap- recommend before performing such an in- pears with the following graphic display: tensive measurement that you check the char- ge capacity of the batteries and replace them if necessary, in particular if the data are of parti cular value or the measured values are critical.
  • Page 10 Zooming in: Click on order to access the 1. Press and hold the left mouse button. Draw a rect- setup for the tempe- angle with the mouse around the section that you rature amd humidity wish to enlarge. axis (Y-axis). 2.
  • Page 11 With these settings the Saving and opening files user determine 1. Click on the icon to open the dialogue window which data he wishes to „File save“ dialogue window. see as the data trace or which grid lines should be added to or removed from the X/Y axes.
  • Page 12 Printing out the graph and list Click on the icon to display the data as a graph. Then click on the icon to print out the graph. Click on the icon to display the data as a list. Then click on the icon to print out the list.
  • Page 13 Trotec GmbH & Co. KG Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-0 +49 2452 962-200 info@trotec.com www.trotec.com...