DL200 H / DL200 D / DL200 L
EN
OPERATING MANUAL
DATA LOGGER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec DL 200 H

  • Page 1 DL200 H / DL200 D / DL200 L OPERATING MANUAL DATA LOGGER...
  • Page 2: Table Of Contents

    In order to use your data logger according to its intended use and utilise its Table of contents complete range of functions, carefully read all documentation about this device. This operating manual describes the functions of the hardware. Content Page A separate manual –...
  • Page 3: Equipment

    3. Equipment Battery compartment Mode selection button Battery cover Data logger with internal sensors (DL 200 H / DL 200 D / DL 200 L) PC connection USB type micro B Network connection RJ45 4. Scope of supply Mount track for fastening...
  • Page 4: Preparation Before Starting

    6. Operation 5. Preparation before starting The PC software SmartGraph is the central configuration interface for your 5.1. Software data logger. All additional configuration and visualisation specifications can only be set by software. 5.1.1. Installation conditions Basic settings can be directly configured with one-button operation by using To configure your data logger and read the recorded measured values, the the mode selection button on your data logger.
  • Page 5: Network Function (M51)

    Operating mode M2 Connect to the network Selection of the operating mode M2 Example display of the operating mode M2 Selection of the network function M51 Example display of the network function M51 Measured value detection is active. The measured values which have been con- If the data logger is connected to a local network and the network function is ac- figured in the SmartGraph software are shown in all three measured value rows tivated, then software configuration and data reading from the data logger can...
  • Page 6: Factory Settings (M52)

    6.2.3. Factory settings (M52) 7. Measured values display and This function resets the device settings data recording to factory settings. Even when resetting the device to factory settings or when there are no batteries 7.1. Sensors, channel groups and in the device, the measurement data re- measuring channels mains in the memory and is not deleted.
  • Page 7: Displaying Measured Values

    Model DL200L 8. Alarm function The DL200L data logger has three internal sensors to detect measured values from a total of seven channel groups. These channel groups (measured values) are: Air temperature in °C, air temperature in °F, dew point in °C, dew point in 8.1.
  • Page 8: Using The Alarm Hysteresis

    8.4. Using the alarm hysteresis Only use appropriate batteries which comply with the technical data. Other types of batteries can cause operating errors. Do not use rechargeable batteries ! If you use the alarm function without alarm hysteresis, then an alarm sounds and is recorded each time the preset limit values are exceeded.
  • Page 9: Technical Data

    10. Technical data Technical data of the data loggers DL200H DL200D DL200L Operating principle Measuring range -20 °C to + 50 °C Air temperature Accuracy ± 0.3 °C (0…40 °C), otherwise 0.5 °C Screen resolution 0.1 °C Operating principle capacitive Measuring range 0 to 100 % RH Relative humidity...
  • Page 10 Trotec GmbH Grebbener Straße 7 52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info @ trotec.com www.trotec.com...

This manual is also suitable for:

Dl 200 dDl 200 l