DL200 X
EN
OPERATING MANUAL
DATA LOGGER
FOR EXTERNAL SENSORS

Advertisement

Table of Contents
loading

Summary of Contents for Trotec DL200X

  • Page 1 DL200 X OPERATING MANUAL DATA LOGGER FOR EXTERNAL SENSORS...
  • Page 2: Table Of Contents

    8.3. Displaying measured values ......9 The DL200X data logger is designed to detect and record a range of measured 8.4.
  • Page 3: Equipment

    Display for inactive measured value recording Display for date Pin 1: Pin 4: GND (reference Display for time Supply sensor potential) Mode selection button (output) Pin 5: n.c. (not connected) Data logger for connecting to external sensors DL200X operating manual for external sensors...
  • Page 4: Scope Of Supply

    The data logger can now be configured via the software. Further detailed information about using the software is provided in the software manual which you can open from the help function of the Smart- Graph software. DL200X operating manual for external sensors...
  • Page 5: The Four Operating Modes

    USB power supply. Measured value detection and data recording are active; but measured value In the optionally available PoE design, the data logger can have its power display is inactive. supplied directly over the network connection. DL200X operating manual for external sensors...
  • Page 6: Factory Settings (M52)

    Briefly pressing the mode selection button closes the message. It is only possible to configure if the data logger is not in logging mode (M3 or M4)! Tip: Note the BUS ID for measuring in the future directly on the sensor. DL200X operating manual for external sensors...
  • Page 7: Logging The Bus Sensors (M7X) Off

    The sensor current is converted into voltage in the DL200X at a load. The load selection button to navigate to the configuration mode M7x. The option for re- has a resistance of <50 Ω. Both the sensor and the DL200X can be supplied via moving the first BUS sensor is shown on the display.
  • Page 8: Pt100 Sensors In 3- And 4-Cable Switching

    A0 / A1 Example LCD displays of sensor specification for registering Important: The DL200X is able to compensate cable resistances up an analogue sensor at the first input channel (AN0): to 10 Ω. The compensation typically reduces the influence of the cable resistance by a factor of 100.
  • Page 9: Measured Values Display And Data Recording

    0.5 µm, particles 1 µm, particles 5 µm, particles 10 µm, particles x µm, particles y µm, particles z µm, unknown, in- sensor types: active, wet-bulb temperature, global radiation, daylight, amount of rain, wind speed, wind direction, analogue/digital input, ground moisture, leaf wetness DL200X operating manual for external sensors...
  • Page 10 Temperature measurement with thermal element J type Temperature °C – Temperature measurement with thermal element J type Temperature °F – Temperature measurement with thermal element S type Temperature °C – Temperature measurement with thermal element S type Temperature °F – DL200X operating manual for external sensors...
  • Page 11: Alarm Function

    Logging mode flashing static Reading the measured value memory Additionally, a hysteresis can be set by which the measured value must return to the valid range to switch off the alarm. DL200X operating manual for external sensors...
  • Page 12: Notes On Maintenance And Operation

    10.8. Cleaning on the display. Afterwards, the display returns to normal operation. The use of aggressive cleaning agents in the vicinity of the DL200X may damage Further detailed information about using the software is provided in the the humidity sensor beyond repair.
  • Page 13: Technical Data

    11. Technical data DL200X data logger for external sensors Measuring range 0 … 1 V Voltage input Accuracy ±200 µV ± 0.1 % of measured value 0 - 1 V Resolution < 500 µV Measuring range 2-cable operation: 4 … 20 mA, 3-cable operation: 0 … 20 mA Accuracy ±...
  • Page 14: Status Codes

    -0.48 mA … 0.00 mA Displayed: 0.00mA 0 … 20 mA Normal operation mode 0.00 mA … 20.00 mA Limit range 20.00 mA … 20.48 mA Displayed: 20.00mA Overcurrent approx. > 20.48 mA 0x52 (CHANNEL_OVERRANGE) DL200X operating manual for external sensors...
  • Page 15 Trotec GmbH Grebbener Straße 7 52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info @ trotec.com www.trotec.com...