  • Page 1 BZ30 OPERATING MANUAL CO₂ AIR QUALITY DATA LOGGER...
  • Page 2: Table Of Contents

    Keep all safety signs, stickers and labels in legible condition. • Do not open the device. • Observe the storage and operating conditions as given in the Technical data chapter. CO₂ air quality data logger BZ30...
  • Page 3 Do not use the device in potentially explosive atmospheres, for casing. Do not overcharge lithium-ion batteries. Only measurements in liquids or at live parts. Trotec accepts no use smart chargers that switch off automatically when liability for damages resulting from improper use. In such a the battery is fully charged.
  • Page 4: Information About The Device

    25 REC indication (measured value detection enabled) 26 HOLD indication (freezing displayed values) 27 MIN indication (display of minimum values) 28 CO2 indication (display of CO value) 29 MAX indication (display of maximum values) CO₂ air quality data logger BZ30...
  • Page 5: Transport And Storage

    Scope of delivery • 1 x Measuring device BZ30 • 1 x 3.7 V Li-ion battery • 1 x Power adapter • 1 x USB connection cable • 1 x CD-ROM with Smartgraph PC software • 1 x Operating manual CO₂ air quality data logger BZ30...
  • Page 6: Operation

        . Start-up Press the  button at the rear of the device for approx. 1 second to switch the device on. The device will then start a warm-up phase lasting 120 seconds. CO₂ air quality data logger BZ30...
  • Page 7 ð After the measured values have been successfully detailed information please refer to the “Using the software” transferred, the data graph window opens. The graph section. shows three channels: CO2 (red), temperature (green) and relative humidity (blue). CO₂ air quality data logger BZ30...
  • Page 8 Opens the dialog window for opening files. Files in ".AsmData" format can be opened. Opens the dialog window for printing files. Opens the dialog window for adjusting the settings. Starts data import from the selected device. Opens the help. CO₂ air quality data logger BZ30...
  • Page 9 In this process, it is irrelevant whether the settings are changed or remain the same. All saved data are permanently deleted when set-up is complete. To save those data before they are deleted, click Cancel and then download the data. CO₂ air quality data logger BZ30...
  • Page 10 Define colours button. 3. Showing/hiding the grid lines Check or uncheck the checkboxes to show or hide the horizontal and vertical grid lines. CO₂ air quality data logger BZ30...
  • Page 11 The individual data points are numbered consecutively. CO value, temperature and relative humidity are indicated for every data point. Displaying the data overview Click the Data overview button to call a summary of the measurement series. CO₂ air quality data logger BZ30...
  • Page 12: Maintenance And Repair

    Directive 2006/66/EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements. CO₂ air quality data logger BZ30...
  • Page 13 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...