Advertisement

Quick Links

DL200 P
EN
OPERATING MANUAL
DATA LOGGER

Advertisement

Table of Contents
loading

Summary of Contents for Trotec DL200P

  • Page 1 DL200 P OPERATING MANUAL DATA LOGGER...
  • Page 2: Table Of Contents

    In order to use your data logger according to its intended use and utilise its Table of contents complete range of functions, carefully read all documentation about this device. This operating manual describes the functions of the hardware. Content Page A separate manual –...
  • Page 3: Equipment

    3. Equipment Battery compartment Mode selection button Battery cover Data logger with internal sensors and additional connections for four external measured value sensors: PC connection USB type micro B 3.5 mm plug socket for external temperature sensor 1 (T1ext) Network connection RJ45 3.5 mm plug socket for external temperature sensor 2 (T2ext) Mount track for fastening BNC connector for external building moisture electrode 1 (BNC1)
  • Page 4: Preparation Before Starting

    5. Preparation before starting 5.1.3 Preparing data logger configuration 5.1. Software If necessary, connect the external measured value sensors which are needed 5.1.1. Installation conditions for detecting measured values to the external connections of your data logger. Information about suitable measured value sensors is provided in the techni- To configure your data logger and read the recorded measured values, the cal data.
  • Page 5: Operation

    6. Operation The PC software SmartGraph is the central configuration interface for your Operating mode M2 data logger. All additional configuration and visualisation specifications can only be set by software. Basic settings can be directly configured with one-button operation by using the mode selection button on your data logger.
  • Page 6: Network Function (M51)

    6.2.2. Network function (M51) Information for system administrators Broadcast over UDP: Requirements for connecting over a IPv4 network. PC sends to ........UDP:255.255.255.255:52010 To automatically identify the IP configuration of a data logger (which has received (data logger receives at UDP port 52010*) an IP address in the IP network via DHCP for example), it is necessary that UDP broadcasts are allowed through the network.
  • Page 7: Measured Values Display And Data Recording

    If either of the operating modes M3 or M4 are selected, then the data logger is in logging mode (REC) and the measured values of the measuring channels se- The DL200P data logger can detect measured values from up to twelve channel lected for recording are saved in the device.
  • Page 8: Alarm Function

    8. Alarm function 8.1. Alarm configuration 8.3. Acoustic alarm An alarm function can be configured in the measuring device administration for If an alarm goes off while the acoustic function is activated (see chapter 6.2.4. each of the measuring channels selected for display or recording. Acoustic function), then and alarm tone sounds and only stops when the mea- sured value returns to the good range.
  • Page 9: Notes On Maintenance And Operation

    9. Notes on maintenance and operation 9.1. Battery change 9.3. Positioning for mobile use If “LO bAtt” appears in the upper row of the display, then the batteries need to For mobile measured value recording, the data logger can be positioned at any be changed.
  • Page 10: Technical Data

    10. Technical data Technical data DL200P air temperature (°C / °F), dew point temperature (°C / °F), internal sensors relative humidity % RH, absolute humidity g/m³ Detectable measured values surface temperature (°C / °F), material temperature (°C / °F), external air temperature (°C / °F), wood moisture (digits),...
  • Page 11: Status Codes

    Technical data external temperature sensor TS 910 Operating principle Measuring range -20 °C to +80 °C Temperature Accuracy 0.2 °C (0…40 °C), otherwise, 0.8 °C Screen resolution 0.1 °C (0…40 °C), otherwise, 0.2 °C Air temperature -20 °C to +50 °C Permissible operating ambient conditions Relative humidity...
  • Page 12 Trotec GmbH Grebbener Straße 7 52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info @ trotec.com www.trotec.com...

Table of Contents