Starting Service Tool; Status Led; Reset Button - Triax TDcH Series User Manual

Compact headnend
Table of Contents

Advertisement

TDcH Compact Headend
Currently the management GUI can be reached at this port. The port is configured to get the IP address via DCHP.
4.1.3

Starting service tool

Open a web browser window.
Enter http://192.168.0.100 in the web address field. Press Enter.
Enter the password. Press the Login button.
Note:
Password = triax1234 when the service tool is opened on each headend for the first
time.
Up to 10 sessions can be opened and logged in to the same TDcH user interface!
If the user does not log out the session will be kept open.
th
When the 11
session is opened the first login session will be closed.
4.1.4

Status LED

Below the reset button there is a general system status LED.
The following status LED indications are available:
Off:
Blinking green:
Blinking orange (green+red): SW update under process
Steady green:
Steady red:
Note:
Please note that the status LED on the Inputs and TV-out is not supported in software version 1.0.
4.1.5

Reset button

The following Reset functions are available:
When the reset button is pressed (during startup) until
the LED blinks green, then the system resets to factory
defaults.
When the reset button is pressed (during startup) until the LED blinks red, then the system starts in recovery
mode.
The system is turned off
The system is starting up
System is up running OK
An error occurs in the system. Log in to the system to get more information
11
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tdch 16s-i-qTdch 16s-q492780492790