Flue outlet collar
S-18F is delivered standard with a top flue outlet
collar.
Rear connection FIG 5-7
Remove rear heat shield by unfastenig top and bottom
screw using a 4 mm Allen key - as shown on FIG 5.
Cut out a perforated hole in the shield to rear outlet
connection - FIG 6.
Remove the rear smoke outlet cover and place it over
the top outlet FIG 7A. Move the smoke collar on the
back of the product and fasten it FIG 7B using a 5 mm
Allen key. Put the back plate back in place, and tighten
the screws holding it in place - FIG 7C - see also FIG 5.
Dissasembling Thermotte FIG
- Carefully pull the lower end of the side plate silightly
up and then pull towards the other side. The same pro-
cedure utilize for second side plate.
- Carefully pull the lower end of the back plate diagonal-
ly towards the door. Leave it at an angle as shown in
the illustration.
- Remove the smoke baffle by moving it carefully to one
side and clear of the rail on the other side. Place the
smoke baffle at an angle and carefully remove it through
the door.
- Remove the back plate by tilting it carefully through the
door.
- Lift the bottom plate up on one side and the the other.
Connecting the flue
Please be aware when connecting the 150 mm flue to
the smoke dome that the flue is placed outside the flue
outlet collar. *Alternative versions exsist due to
National requirements. For the flue connection to the
chimney, follow the recommendations from the chimney
manufacturer
Air supply
For connecting the fresh air supply set see FIG Air mm
Ignitiom air vent control
As an integrated part of the air vent control, S-18F has
a ignition air vent control. By pushing the air vent control
rod to the right (max opening), the ignition air vent con-
trol will be activated.
Attention! After ignition, pull the control back to
normal.
12
A= Ignition air vent
-
Removing the self-closing door mechanism FIG 13
The self closing door mechanism connected to the
stove at the bottom left corner. Carefully unhook the
spring and remove the small screw holding the arm
connected to the door. The self closing mechanism is
now deactivated.
5. Lighting a fire for the first time
When the insert is assembled and all instructions have
been observed, a fire can be lit.
Take care when inserting logs into the burn chamber, in
order not to damage the Thermotte plates.
This will be resolved once the humidity has evaporated.
If needed leave the door slightly open the first 2-3 times
the insert is used.
It is advisable to ventilate the room well when using
for the first time as the varnish on the product may
release some smoke or smell. Both the smoke and
smell will disappear and are not hazardous.
In order to avoid injuries, please be aware that the
surfaface may become hot during operation and
extra care need to be taken to avoid skin burn.
Lighting a fire
Kindling wood
Finely chopped (diameter of 3-5cm)
Length: 25-30cm
Ca. amount pr lighting : 1,2 kg (beech)
Place the air vent control in ignition (FIG A) (Pull out).
Insert small, dry pieces of wood, ignite and ensure the
flames have taken proper hold of the wood. When the
flames are stable and the chimney is warm, push in the
air control out of the ignition mode and regulate the fire
normally.
When there is a glowing layer of ash, new wood logs
can be inserted. Pull the hot ember to the sides of the
combustion chamber when inserting new logs so that
the wood is ignited from the bottom. Insert 2 logs. One
positioned diagonally to the bottom with left end closer
to left front side of window pane. The second leaned
against first one also diagonally in opposite direction.
Set the air vent on 45% air valve opening. The fire
should burn with bright and lively flames.