Outdoor Unit Installation - Midea BREEZELESS Technical Manual

R32 3d inverter control
Table of Contents

Advertisement

piping, signal cable, and drain hose.
3. Connect drain hose and refrigerant piping (refer to
Refrigerant Piping Connection section of this manual for
instructions).
4. Keep pipe connection point exposed to perform the leak
test (refer to Electrical Checks and Leak Checks section of
this manual).
5. After the leak test, wrap the connection point with
insulation tape.
6. Remove the bracket or wedge that is propping up the
unit.
7. Using even pressure, push down on the bottom half of
the unit. Keep pushing down until the unit snaps onto the
hooks along the bottom of the mounting plate.
NOTE:
• Unit is adjustable
Keep in mind that the hooks on the mounting plate are
smaller than the holes on the back of the unit. If you find
that you don't have ample room to connect embedded
pipes to the indoor unit, the unit can be adjusted left or
right by about 30-50mm (1.25-1.95in), depending on the
model.
15mm
(0.59in)
Move to left or right
4. Outdoor unit installation(Side
Discharge Unit)
4.1
4.2
Capacity (Btu/h)
4.3
Fix the outdoor unit with anchor bolts(M10)
15mm
(0.59in)
Cation
Since the gravity center of the unit is not at its physical
center, so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from
deforming.
Do not touch the fan with hands or other objects.
Service space for outdoor unit
Bolt pitch
unit
A
mm
514
12K
inch
20.23
Install Outdoor Unit
B
D
340
333
13.39
13.11
Page 41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents