SPECIFICATIONS
®
The Safe-Cell
Timeflow Push Button Valve is used in prisons, detention centres, high risk institutions,
sporting facilities, schools and public area applications
Time is affected by temperature, flow rate and pressure, and is based on set at 500kPa, 4LPM @ 22˚C.
Once activated, this timed flow product will allow water to flow for approximately 15 seconds*
Designed for easy bench installation (maximum thickness 10mm)
Note: This is a single temperature product, so if warm water is required this needs to be premixed prior to reaching
the valve. This can be done by using a CliniMix
IMPORTANT: All Safe-Cell
in good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
PRE-INSTALLATION
MOUNTING DETAILS
If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown in
rough-in dimensions.
Please note the maximum thickness of the bench/trough is 10mm.
®
Thermostatic Mixing Valve.
®
prison taps are tested in accordance with AS/NZS 3718 and leave our premises
Version 1, 16 March 2017, 1 of 4
½" BSP – Male
½" BSP – Male
Time flow cartridge
Min
100
Max
500
Min
5
Max
70
3 to 4.5
Chrome

Advertisement

loading

Summary of Contents for Galvin Specialised Safe-Cell 50145

  • Page 1 Nominal Flow Rate (LPM) 3 to 4.5 Finish Chrome NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice. PRE-INSTALLATION MOUNTING DETAILS  If the mounting holes do not already exist, mark out and drill the holes in the bench/trough, as shown in rough-in dimensions.
  • Page 2 INSTALLATION IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or tate standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of the product.
  • Page 3 Remove flow restrictor and replace with a satisfactory due to inadequate supply flow restrictor of different capacity to suit pressure (available from Galvin Specialised) Isolation valve is positioned wrong Adjust isolation valve until desired flow is achieved Reduce to below 500kPa (70PSI),...
  • Page 4 Version 1, 16 March 2017, 4 of 4 WARRANTY The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied. Galvin Engineering Pty.