Galvin Specialised Ezy-Drink Lead Safe 170.50.15.01 Product Installation Manualline page 2

Horizontal cam action drinking tap

Advertisement

3
4
PRE-INSTALLATION - MOUNTING DETAILS
If the mounting holes do not already exist, mark out and drill the holes in the wall/sheet, as shown in
rough-in dimensions.
Note: Before installation, all lines must be flushed. We recommend that a line strainer be installed prior to
drinking taps to eliminate any foreign material.
135 NOM
1/2"BSP
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in
accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions
must also comply to the applicable national and/or state standards. Failing to comply with these provisions shall void the
product warranty and may affect the performance of the product.
1. Fit tap assembly
 Fit wall plugs to wall as per rough-in
dimensions.
 When applying thread tape or sealant to the
inlet, ensure the opening is not obscured.
Failure to do so may restrict or block the flow
restrictor, affecting the flow of water.
 Screw tap onto existing spud until the flange is
touching the wall.
 Ensure the outlet is in the correct position and
the holes in the flange align with the wall plugs.
7
6
5
8
11
?
12
10
13
14
15
16
17
15°
ASSEMBLY
(AS SEEN BY USER)
Version 1, 4 February 2020, Page 2 of 4
18
2. Secure the body
 Secure the body with supplied screws.