Component Functions
EEPROM
no
More detailed error code descriptions, causes and remedies can be found in chapter 11.2.
   Condition Monitoring [CM] (0x0092)
Offset parame-
146 (0x0092)
ter
Description
Condition monitoring of ejectors #1 to #16
Index
Index 0 ...15 corresponds to ejector #1...#16
Data type
uint8
Length
16 bytes
Access
Read only
Value range
Byte 1 ...16:
Bit 0 = Valve protection active
Bit 1 = Evacuation time greater than limit
Bit 2 = Leakage rate greater than limit
Bit 3 = H1 not reached in suction cycle
Bit 4 = Free flow vacuum too high
Bit 5 = Manual mode active
Default value
0
Unit
-
EEPROM
no
Offset parame-
146 (0x0092)
ter
Description
CU condition monitoring [part of processdata] (condition monitoring of control
unit)
Index
16
Data type
uint8
Length
1 bytes
Access
Read only
Value range
Bit 0 = Primary voltage limit
Bit 1 = Secondary voltage limit
Bit 2 = Input pressure limit (3.5 ... 5 bar)
Bit 3 = Warning in one or more ejectors
Default value
0
Unit
-
EEPROM
no
IO-Link communication status
This parameter is used to determine the current status of the IO-Link communication at the IO-Link mas-
ter port.
Offset parame-
32 (0x001F)
ter
Description
IO-Link communication status
Index
Index 0 ...1 corresponds to IO-Link master #1 ... #2
Data type
uint8
Length
2 bytes
56 / 94
EN-US · 30.30.01.02237 · 00 · 04/20