Component Functions
State
00 (green)
01 (yellow)
10 (orange)
11 (red)
   Extended Device Status (0x008A)
The category of the pending event code and the current event code itself is displayed.
Extended Device Status Event Category
Parameter
138 (0x008A)
Description
Extended device status – event category
Byte
1+2: Event category of current device status
Access
Read only
Value range
0x10: Device is operating properly
0x21: Warning, low
0x22: Warning, high
0x41: Critical condition, low
0x42: Critical condition, high
0x81: Defect/fault, low
0x82: Defect/fault, high
Extended Device Status – Event code
Parameter
138 (0x008A)
Descrip-
Extended Device Status – Event code
tion
Byte
3+4: Event category of current device status
Data type
uint16
Length
2 bytes
Access
Read only
Value
Event Code
range
0x5100
0x5110
0x5112
0x1812
0x1802
0x1811
0x1000
0x8C01
0x180C
0x180D
0x180E
0x8C20 to 8C2F
0x8D00 to
8D0F
0x8D10 to
8D1F
54 / 94
Description
System is working perfectly with optimal operating parameters
The ejectors are working but maintenance is required
The Compact terminal SCTSi is working but there are warnings
Error – Safe operation of the Compact terminal SCTSi within the operating limits is
no longer ensured (error code is available in the error parameter)
Event Name
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Input pressure too high (> 6.3 bar) or too low
(< 1.9 bar)
Internal error, user data corrupted
Internal error, bus fault
Manual mode is active in at least one ejector
Condition monitoring: primary supply voltage
US outside of operating range
Condition monitoring: secondary supply volt-
age outside of operating range
Condition Monitoring: supply pressure outside
of operating range (3.5 to 5 bar)
Calibration fail, ejectors #1 to #16
Measurement range overrun, ejectors #1 to
#16
Valve protection active, ejectors #1 to #16
Status Category
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Defect/fault, high
Defect/fault, high
Warning, low
Warning, high
Warning, high
Warning, high
Defect/fault, low
Defect/fault, low
Warning, high
Warning, low