Schmalz Compact Terminal SCTSi Operating Instructions Manual page 30

Table of Contents

Advertisement

Interfaces
Designation
Fixed submodule:
Ejector status & control
Optional Submodules:
Designation
Ejector extended values
IOL-E-xx byte
01/02/04/06/08/10/16/24/32
IOL-A-xx byte
01/02/04/06/08/10/16/24/32
IOL-E/A-xx/xx byte
01/01 02/02 02/04 02/08
04/02 04/04 04/08 08/08
16/16 24/24 32/04 32/32
The process data width of each IO-Link master port can, for example, be adapted to the process data
width of the connected device by configuring it with a module with a suitable data length. If no suitable
configuration module is available, the next larger data length should be selected.
It is also possible to configure each IO-Link master port either as a digital input or digital output (C/Q: Pin
4) instead of configuring IO-Link and reading or writing the status via process data.
The configuration is carried out by assigning the appropriate configuration module to the corresponding
port in the controller.
Special Features for Programming Profinet with Beckhoff TwinCAT
Here the slot number for the modules mentioned in the table above is shifted by +1. You must observe
gaps when placing the modules. If there are free slots between slots 5 and 11 (IOLM or DI modules) be-
cause these modules are not available in the device, then you must place empty slots in order to be able
to place ejector modules from slot 11 onwards.
TM
EtherNet/IP
The process data width is fixed and is 445 bytes for input process data and 273 bytes for output process
data, regardless of the actual number of ejectors, DI modules or IO-Link masters of the compact terminal.
For EtherNet/IP, one of the available connection points (identification label or assembly instances) must be
selected. If necessary, the corresponding target address (output/input assembly) must also be specified.
The resulting total process data width depends on the selected connection.
30 / 94
Slot
Subslot 1
Module assign-
ment
Vacuum ejector
IO-Link master
IO-Link master
IO-Link master
Direction
Input/output
Direction
Input
Input
Output
Input/output
EN-US · 30.30.01.02237 · 00 · 04/20
Length in bytes
1+1
Length in bytes
13
1 – 32
1 – 32
1 - 32 + 1 - 32

Advertisement

Table of Contents
loading

Related Products for Schmalz Compact Terminal SCTSi

This manual is also suitable for:

Sctsi-pntSctsi-ectSctsi-eip

Table of Contents