Safety Information
Safety warnings in this manual
In this manual special warnings that are important for the proper and safe use of the products are
clearly identified as follows:
P
DANGER:
Personnel health and injury warnings. Failure to observe the precautions described
here can result in serious health and injury hazards.
E
CAUTION:
Equipment and property damage warnings. Failure to observe the precautions
described here can result in serious damage to the equipment or other property.
General safety information and precautions
The following safety precautions are intended as a general guideline for using the PLC together
with other equipment. These precautions must always be observed in the design, installation
and operation of all control systems.
P
DANGER:
b Observe all safety and accident prevention regulations applicable to your spe-
cific application. Installation, wiring and opening of the assemblies, compo-
nents and devices may only be performed with all power supplies discon-
nected.
b Assemblies, components and devices must always be installed in a shock-
proof housing fitted with a proper cover and protective equipment.
b Devices with a permanent connection to the mains power supply must be inte-
grated in the building installations with an all-pole disconnection switch and a
suitable fuse.
b Check power cables and lines connected to the equipment regularly for breaks
and insulation damage. If cable damage is found, immediately disconnect the
equipment and the cables from the power supply and replace the defective ca-
bling.
b Before using the equipment for the first time check that the power supply rating
matches that of the local mains power.
b Residual current protective devices pursuant to DIN VDE Standard 0641 Parts
1-3 are not adequate on their own as protection against indirect contact for in-
stallations with positioning drive systems. Additional and/or other protection
facilities are essential for such installations.
b EMERGENCY OFF facilities pursuant to EN 60204/IEC 204 VDE 0113 must re-
main fully operative at all times and in all control system operating modes. The
EMERGENCY OFF facility reset function must be designed so that it cannot
cause an uncontrolled or undefined restart.
b You must also implement hardware and software safety precautions to prevent
the possibility of undefined control system states caused by signal line cable
or core breaks.
b All relevant electrical and physical specifications must be strictly observed
and maintained for all the modules in the installation.