1. Route the master valve wire between valve location and Hydrawise controller.
2. Attach the common wire to either solenoid wire. This is most commonly a white colored
wire. Attach a separate control wire to the remaining wire of each master valve
solenoid. All wire splice connections should be done using waterproof connectors.
3. Route wire through the conduit or one of the openings on the bottom of the cabinet.
4. Strip ½" (13 mm) of insulation from ends of all wires. Secure the valve common wire to
"COM" (Common) terminal. Attach the opposite control wire to the M/V terminal.
HC
HPC
Note: With a HC Hydrawise controller, any one of your 6 or 12 zones can be configured to
ON or OFF by Zone or All Zones
ON or OFF by Zone or All Zones