Hunter Hydrawise Ready Manual page 61

Irrigation controllers
Hide thumbs Also See for Hydrawise Ready:
Table of Contents

Advertisement

Flow Meter Body
Adapter
Entry Location
Cable used (shielded cable only)
Flow meter body
Wire Connection
Log in to your account
Create your flow sensor
Creating Alerts
Reading Meter
Testing Meter
Avoid Electrical Interference
in U.S. are shown in US gallons (Int. customers
the dial reads in Cubic Meters). Units can be
changed in App to gallons or liters.
Brass unions included to fit your irrigation system.
Install between the master valve and
zone valves. Meter should be installed
10 times pipe diameter before and 5
times after with straight pipe and no
fittings. See example:
18 gauge - 1000 foot max Length. Shielded
direct burial cable must be used. Cable should
consist of two dedicated wires and must not be in
the same conduit, cable bundle or trench as the
solenoid wires. DO NOT share common wire.
Shielded cable is commonly available, here are
some manufacturers (Paige
additional information on avoiding electrical
interference, see below:
Arrow indicates direction of flow.
Blue/White wire only, red not used. See sensor
configuration
controller.
Enter your login
App will show options for all HC meters.
See link here
See link here
See link here
Copyright 2020 Hunter Industries. All Rights Reserved.
Pipe
10x-Before
3/4"
7.5"
1"
10"
1.5"
15"
2"
20"
for more info based on model
[35]
information.
[15]
[36]
[37]
[38]
5x-After
3.75"
5"
7.5"
10"
& Regency
For
[33]
[34]
61