wiring is not polarity sensitive. As long as you have one wire in a Sensor Port and a
Sensor Common, the device will work correctly. For flow meters that use three wires and
meet the specs above, configure the wiring until you find the two correct wires to use.
Single Flow Meter - Sharing Two
Controllers
For this installation, we suggest a few tips to make sure you do not receive any
unnecessary alerts.
When using multiple controllers on the same flow meter, there are two alerts we do not
recommend using.
1. High Flow Leak - High water usage with no zones running.
2. Slow Leak - Water usage over last hour with no zones running.
These alerts are controller specific so when the controller with the flow meter is not in
operation, it does know about the other controller operation.
Tips:
1. The inter station delay
higher.
2. Change the gallons in the alert to be higher (e.g. alert from 5 gallons to 20 gallons).
Following these parameters should allow the system to run normal when using one flow
meter with multiple controllers.
should be set for 10-30 seconds. We do not recommend any
[44]
Copyright 2020 Hunter Industries. All Rights Reserved.