Table 8-1. Troubleshooting Information (cont.)
Symptom
Possible Cause
Output voltage does
The most common cause of this
not match input data
problem is that the I/O bus speed
is in excess of 8 MHz.
An open connection exists.
Another system resource is using
the specified base address.
Computer does not
Board not seated properly.
boot.
The base address setting of the
DAC-02
of another system resource.
The power supply of the host
computer is too small to handle
all the system resources.
System lockup
A timing error occurred.
If your board is not operating properly after using the information in
Table 8-1, continue with the next two sections to further isolate the
problem.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Possible Solution
Reduce I/O bus speed to a maximum of
8 MHz (to change the I/O bus speed, run
BIOS setup). See the documentation for
your computer for instructions on
running BIOS setup.
Check wiring to screw terminal.
Reconfigure the base address of the
DAC-02
more information. Check the I/O
assignments of other system resources
and reconfigure, if necessary.
Check the installation of the board.
Check the base address settings of your
board conflicts with that
system resources; each address must be
unique.
Check the needs of all system resources
and obtain a larger power supply.