2.0
INSTALLATION
2.1
DETECTOR PLACEMENT
Here is a list of locations that you will want to have your Argus system installed, listed in
order of priority. Keep in mind that the needs of a gin are different from one to the next,
and if you need help choosing locations, contact a Samuel Jackson representative.
• Lint flue – Past all lint cleaners, preferably in round pipe rather than rectangular.
• Gin stands
• Overflow – Right before the separator
• Trash – Before the trash fan
• Seed – Gravity dropper
• Precleaning – Before inclines or separators
• Motes – Before the mote separator/cleaner
• Condenser outlet – Inside the building
Locations to Avoid:
• Immediately after any precleaning equipment
• Near windows
• Near access doors that are opened often
• Near free air gates
Ideally detectors should be installed on access doors to allow for easy maintenance and
periodic cleaning (see 5.2).
Argus Installation and Resource Guide
INSTALLATION
11