8.

Actuator Assignment and Cable Cross-Sections

8.1

Part-Turn Actuators

Average
Electronic
power
unit
dissipation of
electronic unit
EAS822
60 W
60 W
75 W
60 W
EBS852
80 W
80 W
80 W
80 W
80 W
100 W
EBS862
115 W
on request
Table 2:
8.2

Linear Actuators

Average
Electronic
power
unit
dissipation of
electronics
EAS 822
60 W
55 W
60 W
60 W
EBS 852
75 W
75 W
80 W
80 W
100 W
EBS 862
115 W
115 W
Table 3:
1)
At rated actuator power; current consumption in positioning mode around 40 ... 50% of I
2)
Cable length between electronics and actuator. Cross-sectional area of signal cable 0.5mm
10
Max. current
1)
consumption
Actuator
115 V
230 V
1.0 A
0.55 A PME120
1.8 A
0.90 A RHD250-10
2.2 A
1.1 A RHD500-10
3.4 A
1.7 A RHD800-10
6.0 A
3.0 A RHD1250-12
4.8 A
2.4 A RHD2500-25
4.0 A
2.0 A RHD4000-40
4.0 A
2.0 A RHD8000-80
--
5.3 A RHD2500-10
--
10.0 A RHD4000-10
--
9.0 A RHD8000-12
--
10.2
RHD16000-30
Max. current
1)
input
115 V
230 V
1.0 A
0.55 A
LME 620
3.4 A
1.
RSD10-5.0
3.8 A
1.9 A
RSD10-10.0
4.8 A
2.4 A
RSD20-5.0
3.8 A
1.9 A
RSD20-7.5
4.0 A
2.0 A
RSD50-3.0
4.4 A
2.2 A
RSD100-1.5
5.0 A
2.5 A
RSD200-0.7
--
6.4 A
RSD50-10.0
--
12.5 A
RSD100-10.0
--
13.5 A
RSD200-5.0
Cross-sectional area of motor cable /
permissible length in [m]
2
1.5 mm
2.5 mm
180
270
160
70
Cross-sectional area of motor cable /
permissible length in [m]
Actuator
2
1.5 mm
2.5 mm
180
270
160
70
2)
2
2
2
4 mm
6 mm
300
480
-
460
-
-
270
430
-
120
190
280
2
2
2
4 mm
6 mm
300
480
-
460
-
-
270
430
-
120
190
280
2
10 mm
-
-
-
460
2)
2
10 mm
-
-
-
460
max.
2
.

Advertisement