Aereco VBP+C4 Installation And Maintenance Manual

Hybrid assistance ventilation fan

Advertisement

Quick Links

Installation and maintenance
VBP+C4
Hybrid assistance ventilation fan
TF6751_D
EN - Document not contractual. Aereco can realise technical modifications on its products without prior notice.
TF6751_D
ENGLISH

Advertisement

Table of Contents
loading

Summary of Contents for Aereco VBP+C4

  • Page 1 Installation and maintenance ENGLISH VBP+C4 Hybrid assistance ventilation fan TF6751_D EN - Document not contractual. Aereco can realise technical modifications on its products without prior notice. TF6751_D...
  • Page 2: Table Of Contents

    MS mode ..........................24 5.3. Installation check up ......................25 MAINTENANCE ........................... 26 6.1. Prior warnings ........................26 6.2. Maintenance and cleaning ..................... 26 Technical Assistance ........................27 Warranty ............................28 Protection of the environment ...................... 28 TF6751_D Aereco S.A.
  • Page 3: Introduction

    ▪ The number of fans and their arrangement must be studied so as to ensure the proper operation of the system. ▪ In general, barring special cases, all ducts of a given stack of housing units must be equipped with one or more fans. TF6751_D Aereco S.A.
  • Page 4: General

    ▪ Individual setting/adjustment of the speed of each fan according to the site configuration (number of storeys, ductwork...) ▪ Speed control of each fan according to the temperature, (item sold by Aereco), wind or by using a clock (items not sold by Aereco) ▪...
  • Page 5: Product Data

    3: Metal protection for the control unit Note: the MS mode also requires two specific modules, a temperature probe and other electrical components. These elements are described in the manual specific to this mode 2 Delivered connected to the fan TF6751_D Aereco S.A.
  • Page 6: Dimensions

    6/28 2.2. Dimensions Dimensions in mm. VBP+ C4 fan control unit and its metal protection: TF6751_D Aereco S.A.
  • Page 7: Technical Data

    Number of suction connections available Output/discharge ø354 Installation On roof, head of duct - 3 ø8mm screws Operation Turbine drive By motor coupler Maximum speed of rotation Accessories Module “FAN” (code VB21118) et Modules module “MAIN” (code VB21119) TF6751_D Aereco S.A.
  • Page 8: Installation

    ▪ The adaptation components must be made of a material strong enough to bear the weight of the fan(s). ▪ The latter must be fastened to the stack securely and so as to assure a good seal with it; the plenum as a whole must also be perfectly sealed. TF6751_D Aereco S.A.
  • Page 9: Fixing Of The Fan Control Unit

    When installing the control unit on a horizontal face, it is necessary to maintain a distance between 50 mm and 550 mm between the fan housing and the metal protection of the control unit. To make the VBP+ F400 compliant, every electrical cable linked to the control unit must be 400 °C resistant. TF6751_D Aereco S.A.
  • Page 10: Case Of An Individual Duct

    ▪ ensure a height of air of at least 180mm between the end of the stack and the outlet section Ø350 mm. ▪ The fan must be centered on the outlet section Ø350 mm. Example of a typical stack of the collective and individual type: TF6751_D Aereco S.A.
  • Page 11: Case Of Ducts Grouped Under 2 Fans

    ▪ Each 350 mm outlet must be at least 1,000 mm from the other and at least 500 mm from the bulkhead separating the volumes. The plenum must provide 2 virtual platforms measuring at least 800 x 600 mm each (see example below). Example of grouping of 8 individual ducts: TF6751_D Aereco S.A.
  • Page 12: Limits

    ▪ Soot door. This is generally located on the side of the stack or of the plenum. ▪ Top plate tipping system (with hinges and catches). ▪ Attachment that can be removed from and refitted on the top plate. TF6751_D Aereco S.A.
  • Page 13: Installing The Fan

    ▪ Use only the 2 handles located under the uprights to handle the fan. ▪ Wear suitable gloves (some of the metal parts may be sharp) ▪ Do not set the fan down on an obstacle that might damage the turbine. ▪ Do not lay the fan flat (horizontally) TF6751_D Aereco S.A.
  • Page 14 3) Loosen the 4 screws and take off the cap 4) Check the couplig alignment between motor axis and turbine axis. The coupling piece must fall down freely between both axes without any friction until the thread turbine axis. TF6751_D Aereco S.A.
  • Page 15 5) In case it does not fall down freely, loosen the 3 nuts (see below) and realign the motor plate so that the couplig falls down freely from the motor axis to the turbine axis. 6) Gradually, tighten the 3 nuts with a torque wrench to 7.5 Nm. Tightening must be done one by one per occurrence. TF6751_D Aereco S.A.
  • Page 16 7) Once the 3 nuts are tightened, check that the couplig is still able to fall down freely from the motor axis to the turbine axis without any friction. 8) Tighten the coupling screw on the turbine shaft using the torque wrench to 4.6 Nm TF6751_D Aereco S.A.
  • Page 17 Warning : The flat part of the axis motor must be placed at the opposite side from the tightening coupling screw 10) Place a gasket* as a seal between the top plate and the base of the fan. *provided on some versions TF6751_D Aereco S.A.
  • Page 18 - Loosen the 4 screws that are maitaining the protective ▪ driver box to the plate support. - Set the plate on the plenum - Put back the support box horizontally or vertically by tightening the 4 screws TF6751_D Aereco S.A.
  • Page 19: Connections

    Case B = 230 VAC power supply box located near the fans on the terrace. ▪ Mode ST: ▪ Case A = 230 VAC power supply box away from the fans (example in the stairwell). Case B = 230 VAC power supply box located near the fans on the terrace. ▪ TF6751_D Aereco S.A.
  • Page 20 20/28 Mode MS: ▪ Case A = 230 VAC power supply box away from the fans (example in the stairwell). ▪ Case B = 230 VAC power supply box located near the fans on the terrace. TF6751_D Aereco S.A.
  • Page 21: Power Connection

    To make the VBP+ F400 compliant, every electrical cable that can be in contact with the plenum must be resistant for a temperature of 400°C. 230 VAC Power connection TF6751_D Aereco S.A.
  • Page 22 3 Grounded, this strap participates to the CEM reduction from the product itself and limits the danger in the case of the cable leading to the motor is cut off (secondary evacuation device TF6751_D Aereco S.A.
  • Page 23: Starting Up/Operation

    Do not touch anything; the appliance will itself initiate a starting cycle, until it starts. To access the fan speed control potentiometer in ST mode: Unscrew the reductor, adjust the potentiometer and screw in the reductor sufficiently to keep the reductor waterproof. Speed control Adaptator potentiometer TF6751_D Aereco S.A.
  • Page 24: Ms Mode

    The motor technology used may lead to starting errors. If this happens, the appliance fails to start and begins vibrating slightly. Do not touch anything; the appliance will itself initiate a starting cycle, until it starts MS mode Driving side TF6751_D Aereco S.A.
  • Page 25: Installation Check Up

    Check that the numbered modules are connected to the equivalent fans (Module 1 to fan 1, etc.) Check the speed setting of the fan modules (according to the □ instructions) □ Check the group configuration (see module manual) TF6751_D Aereco S.A.
  • Page 26: Maintenance

    DO NOT CUT the metallic staple linking the access hatch to the support. 2) Open to clean the inside of the fan. 3) Close the access hatch and put some new plastic clips. TF6751_D Aereco S.A.
  • Page 27: Technical Assistance

    The fan makes anormal noise The coupling is damaged Check the coupling’s condition (visual control) In case actions mentionned above does not solve the issue, or for any other question, please contact your retailer. TF6751_D Aereco S.A.
  • Page 28: Warranty

    This appliance is guaranteed for two years, counting from the date of purchase, against any manufacturing defects. In this context, Aereco replaces the appliance or supplies the parts found to be defective after appraisal by its customer service department. In no case does the warranty cover other expenses, such as labour costs, travel, or indemnification of any kind.