STEP9:
Connect the 13V external power supply to the controller,
1)
The voltage should be between 12-14V with the current at:
H-100 --------------------------- 1.5A
H-200 --------------------------- 3A
H-300 --------------------------- 4.5A
H-500 --------------------------- 5A
H-1000 ------------------------- 10A
STEP10:
Connect the Hydrogen supply to the hydrogen supply valve, and make sure the closed hydrogen
pressure is between 0.45-0.55Bar.
Warning:The tube between the hydrogen pressure regulator and the fuel cell gas input is
required to be less than 30cm.
Make sure the Hydrogen gas to be used is ≥99.995% purity and the other gas(es) within the gas
supply are not a Sulphic composition or other gases such as CO or CH4, which can all poison the
fuel cell, reducing its performance dramatically.
STEP 11:
Check the following steps before starting the system:
1.
The connection between the hydrogen input valve and the hydrogen source.
2.
The connection between the hydrogen input valve and the stack intput.
3.
The connection between the stack outoput and the purging valve.
4.
The output tube of purging valve is kept away from the stack.
5.
The 8pin plug connection between the stack and the controller.
6. The "FC+/-" connection between the stack and controller.
7.
The input hydrogen pressure is 0.45-0.55Bar.
8.
The external battery is providing 12-14V.
9.
The load is below 1000W.
H-1000 Fuel Cell Stack User Manual V4.4
The System is now setup and ready to be used.