Defrosting
The appliance keeps free from ice inside because of
the NoFrost System. A defrosting procedure isn´t
necessary.
Changing the bulb
CAUTION:
Do NOT remove the cover of the interior light.
The LED light may be replaced / repaired in case of
failure / defect only by an authorized specialist.

Troubleshooting

Before you contact an authorized specialist
Problem
Cause / Action
Unit is not
∙ Check the power supply / tem-
working
perature setting / ambient temper-
properly or
ature. ∙ Unblock the ventilation
at all
openings, install the unit freely.
Loading is
∙ Check the temperature setting /
too warm
ambient temperature. ∙ Open the
door only as long as necessary.
Loud noise
∙ Check the appliance position.
during opera-
∙ See the section "Operating
tion
noise".
Water on the
∙ Check the temperature setting.
unit bottom
Light does
∙ Check the power supply.
not work
∙ See "Changing the bulb".
Error codes
With some malfunctions, the display shows error
codes!
Code
Causes
Display communication failure
E0
E1
Temperature sensor failure fridge section
E2
Temperature sensor failure freezer section
E3
Defrosting sensor failure
E5
Defrost heater failure
NOTE:
If a problem persists after following the steps above,
contact your trader or an authorized technician.

Technical Data

Climate class SN/N/ST: this appliance is intended to
be used at ambient temperature ranging from 10°C
to 38°C.
Electrical connection............................................
Power voltage: .........................220-240 V~ / 50 Hz
Rated (defrost) power: ................................240 W
Rated current: .............................................1.5 A
Dimension H x W x D / Weight...............................
Appliance size: .....................177.0 x 90.0 x 66.0 cm
Net weight: ...................................approx. 88.0 kg
For more information about the product, scan the QR
code on the supplied energy label and/or visit the
official website of the product data bank:
https://eprel.ec.europa.eu
The right to make technical and design modifications
during continuous product development remains
reserved.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.