Schematic Diagrams; Alt. 1. Connection To The Ctc Controlling Product, Common Underfloor Heating/Cooling - CTC Union EcoComfort Installation And Maintenance Manual

Passive cooling unit
Table of Contents

Advertisement

2. Schematic diagrams

2.1
Alt. 1. Connection to the CTC controlling
product, common underfl oor heating/cooling
The diagram shows schematically how CTC EcoComfort is connected to the systems; additional
equipment, such as expansion vessels, shut-off valves, safety valves, buffer tank etc., is not shown
here. The controlling product in this example is the ground source heat pump CTC GSi. In this
example (Alt.1), the diverting valve Y60 is connected to the combined heating/cooling circuit as well
as to the controlling product and CTC EcoComfort. The diverting valve is controlled by the controlling
product.
Controlling
product
7
10
CTC EcoComfort
15
Y60
M
1
2
19
3
5
6
17
9
8
16
10
18
1.
12
13
2.
3.
4.
5.
4
M
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
11
20
Circuit 1, combined
heating/cooling
CTC EcoComfort passive cooling
unit
Heat exchanger
Bleeding valve
Mixing valve with motor
Non-return valve, cooling unit
Built-in circulation pump
Evaporation heat exchanger in the
controlling product
Brine pump in the controlling
product
Non-return/throttle valve, main
system
Filling equipment
Bore hole with collectors
Circulation pump
Primary fl ow sensor
Outgoing pipe from the controlling
product
Return pipe from heating system
To bore hole
From bore hole
Heating system
Diverting valve
Room sensor