4.
Incorrect supply voltage: check if the mains voltage matches the required volt
age on the nameplate.
5.
The water level has dropped too low; make sure that the suction height is
correct.
6.
Blown fuse or thermal protection has tripped the pump; replace the fuse or
allow the thermal protection to cool down.
7.
Fuse impeller is worn out; take the pump to your customer service
8.
Foot valve is above the water level; make sure the suction hose is properly
submersed.
9.
Pump has not had enough time to prime; fill the pump housing with water.
10.
Space is poorly ventilated; provide adequate ventilation and/or cooling.
11.
Air in the system; seal connections and connectors properly.
12.
Injector is clogged; take the pump to your customer service.